IPDB › China Industry › Instruments & Meters
China, Chinese Macylab-Factory Determination of Gold Ore High Precision Dual System Icp-Oes-Spectrometer Manufacturer1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Optical Lens InstrumentSpectrometerIcp-OesInductively Coupled Plasma
Macylab Instruments Inc.
Preview:
Product Description Product Description Inductively coupled plasma emission spectrometer(ICP6800) developed by Macylab Instruments with many years of technology accumulation. It is used to measure traces and traces of various substances (dissolvable in hydrochloric acid, nitric acid, hydrofluoric acid, etc.),and the content of metal elements or non-metallic elements. It is stable and reliable and with high degree of automation and easy operation.At present, instruments are widely applied in various fields such as rare earth, geology, metallurgy, chemical industry, environmental protection, clinical medicine, petroleum products, semiconductor, food, biological samples, criminal science, agricultural research and so on.Product ParametersApplication EnvironmentCONTENT RANGEShipping/Storage Ambient Temperature 15oC-25oCShipping/Storage Relative Humidity ≤70%Atmospheric pressure 86-106 kPaPower Supply 220±10V 50-60MHzWorking Humidity ≤70%Working Temperature 15oC-30oC RFPower technical parameter:Circuit type: solid-state RF power supply, with function of automatchFrequency: 27.12MHz±0.05%Frequency Stability: <0.1%Power Output: 800W-1200WPower Output Stability: <0.3%Escaped RF radiation: 30cm away from the instrument, electric field: E<2V/m Sampling System Technical Parameter:Output working coil inner diameter :25mmTorque tube: Three concentric, external diameter 20mmCoaxial nebulizer:Outer diameter 6mmDouble barrel atomizing chamber: Outer diameter 34mm Gas Flow Controls1. Plasma Argon Flowmeter:(100-1000)L/h (1.6-16L/min)2. Auxiliary Argon Flowmeter:(10-100)L/h (0.16-1.66L/min)3. Carrier Argon Flowmeter(10-100)L/h (0.16-1.66L/min)4. Pressure Maintaining Valve(0-0.4MPa)5. Cooling Water:Temperature: 20-25oC, Rate of Flow>5L/min, Hydraulic Pressure>0.1MPa SpectrometerOptics:Czerny-Turner typeFocal length: 1000 mmGrating: Ion Beam Etching Holographic Grating, 3600L/mm or 2400L/mmReciprocal linear dispersion: 0.26nm/mmResolution:≤ 0.007nm (3600 line grating);≤0.015nm (2400line grating) ElementWL(nm)Limit ElementWL(nm)LimitLa408.672<3.0 Cr267.716<5.0Ce413.765<5.0 Al396.152<5.0Pr414.311<5.0 Zr343.823<5.0Nd401.225<5.0 Ag328.068<3.0Sm360.946<10.0 Sr407.771<1.0Eu381.967<1.0 Au242.795<5.0Gd342.247<10.0 Pt265.945<5.0Tb350.917<3.0 Pd340.458<5.0Dy353.170<3.0 Ir224.268<10.0Ho345.600<3.0 Rh343.489<10.0Er337.271<3.0 Ru240.272<5.0Tm313.126<3.0 Ba455.403<1.0Yb369.419<1.0 As228.812≤15Lu261.541<3.0 Sb206.833≤15Y371.030<1.0 Bi223.061≤10Sc335.373<1.0 Hg253.652≤15Ta226.230<5.0 Pb220.353≤15Nb313.340<5.0 Ga294.364≤10Mn257.610<3.0 Se203.985≤10Mg279.553<1.0 Sn242.949≤20B249.773<10.0 Te214.281≤10Zn213.856<3.0 Ta226.230≤5.0Co228.616<3.0 Th283.730≤10Si251.611<10.0 Tl276.787≤30Ni232.003<5.0 Re227.525≤5Cd226.502<3.0 Ge209.426≤15Fe239.562<3.0 Os225.585≤1Ca393.366<1.0 W207.911≤10Mo281.615<5.0 Cu324.754<3.0V310.230<5.0 Li670.784≤3Be313.041<1.0 Na588.995≤20Ti334.941<3.0 K766.490≤60 Wavelength range: 3600 line grating:(190nm~500) nm;2400 line grating: (190nm~800) nmMinimum pace of stepping motor: ≤0.0006 nmExit Slit:12μm;Entrance Slit:10μm Photoelectric Converter PerformancePhotomultiplier tube specification: R293/R928Negative HV on PMT: 0-1000V;Stability: <0.05% Overall PerformanceWavelength range of scanning: 195nm~500nm(3600L/mm line grating);195nm~800nm(2400L/mm line grating)Repeatability: RSD(Relative Standard Deviation)≤1.5%Stability: RSD(Relative Standard Deviation) ≤2%Detection Limits (μg/L): The detection limit of 36 elements (ug/ml)ElementWavelength(nm)Detection limit ElementWavelength(nm)Detection limit ElementWavelength(nm)Detection limit ElementWavelength(nm)Detection limitLa408.6723.0 Ho345.6003.0 Mn257.6103.0 Ca393.3661.0Ce413.7655.0 Er337.2713.0 Mg279.5531.0 Mo281.6155.0Pr414.3115.0 Tm313.1263.0 B249.77310.0 V310.2305.0Nd401.2255.0 Yb369.4191.0 Zn213.8563.0 Be313.0411.0Sm360.94610.0 Lu261.5413.0 Co228.6163.0 Ti344.9413.0Eu381.9671.0 Y371.0501.0 Si251.61110.0 Cu324.7543.0Ga342.24710.0 Sc335.3731.0 Ni232.0035.0 Cr267.7165.0Tb350.9173.0 Ta226.2305.0 Cd226.5023.0 Al396.1525.0Dy353.1703.0 Nb316.3405.0 Fe239.5623.0 Zr343.8235.0 Radio-frequency signal generator (RF)Inductive feedback type self-oscillation circuit, coaxial-cable output.Match and tune, take the power feedback to proceed automatic closed-loop control.Samples introduce system. Three concentric quartz torch tubes.Scanning optical splitter.1000mm/750mm focal distance ion etching holographic grating.Main features(1). High stability of RF (radio frequency) output, light source is stable, detection limit is low, the minimum value can be reaching PPb (Parts per Billion). (2). The range of linearity of the work curves is wide, which can reach from 5 to 6 orders of magnitude.(3). Multi-elements analysis at the same time, fast and application area is wide. It can analyze all the metallic elements and some nonmetallic elements of the periodic table of elements. Software Introduction:TY-9800 Type ICP Spectrometer uses analysis & operation software, operation is convenient and fast, function is powerful, test, data processing, correction and data output etc. can be realized at the same time.Software function includes standard curve,search the peak automatically, build analytical method. One-stop Shopping Certifications Company Profile Macy(China) Instruments Inc is part of Shanghai Macylab Instrument Inc, is a high-tech enterprise with independent intellectual property rights . Macy hold the pioneering concept "technology - because you change " , and as a business purpose, and constantly explore, bold innovation. Especially in the field of analytical instruments ,Macy constantly develop advanced products that enable Macy to become a high-quality instrument resource supplier and leader. Factory Established in Shanghai in 2012, Macylab Instruments Inc. has three R&D(research and development)and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries,The company's main products are ultraviolet visible spectrophotometer, atomic absorption spectrometer, atomic fluorescence photometer, ICP-AES/ICP-MS, inductively coupled plasma emission spectrometer, ultra micro spectrophotometerExhibitionFAQQ1: Why choose Macy Lab?A1: Professional manufacturer with more than 10 years experienceMainly exported to the European and American markets, and we are also involved in other markets.Q2: Are you a factory or a trading company?A2: We are professional manufacturer of UV/Vis Spectrophotometers, Atomic Absorption Spectrophotometer, Micro-volume UV/VIS spectrophotometers , ICP item and Nucleic Acid Automatic Extraction System. And we have three R&D and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries.Q3: OEM , ODM acceptable or not?A3: Absolutely, yes.Q4: What can i get the price?A4: Usually we quote within 12 hours after we get your enquiryQ5:What are your Delivery terms?A5: We accept FOB,EXW,CFR . You can choose the one which is most convenient or cost-effective for you.Q6: What about the after-sale service?A6: Our spectrophotometer consumables are fully equipped, good after-sales service system and one-year warranty commitment, which can solve customer's worries.We can ensure our customers to purchase the components and parts within 5 years. And the product updates and replacement will not be affected.Q7: What about the M.O.Q?A7: Usually we don' t have M.O.Q, we can offer even only 1 unit, while , you are welcome to order in bulk, and we are quite pleasure to offer a big discount.Q8: Sample order is OK?A8: Sample order is no problem.Q9: What' s kind of shipment for customer choosing?A9: Usually ship by sea, by air.We can also provide reasonable solutions according to your transportation requirements.Q10: Are your operation keypad, interface, software and manual in English version?A10: Yes, its operation keypad, interface, software and manual in switching interface between Chinese and English. Q11: What areas and applications can it be used?Q11: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.Q12: Which payment can be acceptable ? A12: We could accept the payment by T/T, Paypal, Western Union,L/C, etc.Q13: What is the delivery time?A13: Normally 15-30 days,specific delivery date would depend on the production season and order quantity.Q14: Can I get a sample?A14: Yes,please contact our staff for more information.Q15: How about OEM and ODM?A15: More than 10 years experience in OEM and ODM.Q16: What kinds of models do you make ?A16: We specializing in various optical analyzer. Including Atomic Absorption Spectrophotometer,Ultraviolet and Visible Spectrophotometer,Atomic fluorescence photometer,ICP-AES/ICP-MSQ17: What standard accessories are included?A17: Main unit, 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), With user manual and power cable.Q18: Is PC software included?A18:The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.Q19: Why the reading is red and reach its maximum value 3.00Abs?A19: Probably you use the glass cuvette in UV range.Q20: Why the wavelength calibration or self checking fail?A20: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.Q21: Why is the reading is not as accurate as before?A21: Do the wavelength calibration before testing or restore the device to its default factory settings.Q22: Why PC software can not be installed successfully?A22: Close your anti-virus software on the computer and do it again.Q23: Why the software can not be connected successfully?A23: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.Q24: Can the data transferred to USB or PC?A24: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.Q25: Why the Abs value is negative(lower than zero).A25: Do the blanking or change the reference sample.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...