IPDB › China Industry › Instruments & Meters
China, Chinese Victor 26h Multifunction Process Calibrator with Hart Communication Digit Display Process Calibrator Signal Generator1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
DetectorLife DetectorDigital MultimeterClamp Meter
Shinningpc Industrial Co., Ltd.
Preview:
Product Description VICTOR26H Multifunction Process Calibrator HARTCommunication With Accuracy 0.01% 5 Digits Display 24V loop circuit IP65Protection Grade: IP65Multifunction Process Calibrator with HART CommunicationStatement: this is applied to both HART type and Basic type multifunction process calibrators. Illustrations concerned with HART operations can be applied only to HART type. All explanations and examples are made on HART type. Standard AccessoriesMake sure that the package contains all the accessories listed below. And if you find they are damaged or any of them is missing,please contact the vendor from which you purchased the product as soon as possible. Refer to the replacing part list in 15.3 inthe Manual if you want to order the replacing parts.§ One pair of Testing Probe(H000000-00)§ One pair of Industrial testing Lead(H000001-00)§ One pair of Industrial testing Lead (H000002-00)§ One pair of hook Testing Probe (H000004-00)§ One pair of Alligator clip(H010000-00)§ One pair of Alligator clip(H010007-00)§ One set of RTD Convertor(H200000-00)§ One copy of A User's Manual§ One copy of Certification of Warranty§ Two pieces of Fuse Tube(100mA/250V)§ Two pieces of Fuse Tube(50mA/250V)§ Four alkaline batteriesOne BagSpecificationProjectModelPerformanceparametersVICTOR 26VICTOR 26HSourceDC millivoltRange-5 ~ 110mV-5 ~ 110mVAccuracy=±(% of the set value+% of range)0.01%+0.01%0.01%+0.01%Resolution1uV1uVDC voltageRange-1 ~ 11V-1 ~ 11VAccuracy=±(% of the set value+% of range)0.01%+0.01%0.01%+0.01%Resolution10uV/0.1mV10uV/0.1mVDC currentRange0 ~ 33mA0 ~ 33mAAccuracy=±(% of the set value+% of range)0.01%+0.01%0.01%+0.01%Resolution1uA1uASink currentRange0 ~ 33mA0 ~ 33mAAccuracy=±(% of the set value+% of range)0.01%+0.01%0.01%+0.01%Resolution1uA1uAExternal powersupply5 ~ 28V5 ~ 28VResistanceRange0 ~4KΩ0 ~4KΩAccuracy=±(% of the set value+% of range)0.01%+0.01%0.01%+0.01%Resolution0.01Ω/0.1Ω0.01Ω/0.1ΩThermocoupleRangeR/S/K/E/J/T/B/N/L/UR/S/K/E/J/T/B/N/L/UAccuracy0.4oC0.4oCResolution0.1oC/1oC0.1oC/1oCRTDRangePt100/Pt200/Pt500/Pt1000/Cu10/Cu50Pt100/Pt200/Pt500/Pt1000/Cu10/Cu50Accuracy0.2oC0.2oCResolution0.1oC0.1oCFrequency(Hz)Range1Hz ~110KHz1Hz ~110KHzAccuracy±2words±2wordsResolution0.01Hz/1Hz/0.1KHz/2KHz0.01Hz/1Hz/0.1KHz/2KHzFrequency(CMP)Range60~1200 CPM60~1200 CPMAccuracy±2words±2wordsResolution1CPM1CPMPulseFrequency1Hz ~10KHz1Hz ~10KHzRange1 ~100000cyc1 ~100000cycAccuracy±2words±2wordsResolution1cyc1cycSwitchRange1Hz ~110KHz1Hz ~110KHzAccuracy±2±2Resolution0.01Hz/1Hz/0.1KHz/2KHz0.01Hz/1Hz/0.1KHz/2KHzPressureRangeDepends on the pressure moduleDepends on the pressure moduleAccuracy=±(% of the set value+% of range)Depends on the pressure moduleDepends on the pressure moduleResolution5 digit display5 digit displayMeasurementDC millivoltRange-5 ~ 550mV-5 ~ 550mVAccuracy=±( % of Reading+ % of Range)0.01%+0.01%0.01%+0.01%Resolution1uV/10uV1uV/10uVDC voltageRange-0.5 ~ 35V-0.5 ~ 35VAccuracy=±( % of Reading+ % of Range)0.01%+0.01%0.01%+0.01%Resolution0.1mV/1mV0.1mV/1mVDC currentRange-5 ~ 55mA-5 ~ 55mAAccuracy±( % of Reading+ % of Range)0.01%+0.01%0.01%+0.01%Resolution1uA1uAResistanceRange0 ~5.5KΩ0 ~5.5KΩAccuracy=±( % of Reading+ % of Range)0.01%+0.01%0.01%+0.01%Resolution0.01Ω/0.1Ω0.01Ω/0.1ΩThermocoupleRangeR/S/K/E/J/T/B/N/L/UR/S/K/E/J/T/B/N/L/UAccuracy0.7oC0.7oCResolution0.1oC/1oC0.1oC/1oCRTDRangePt100/Pt200/Pt500/Pt1000/Cu10/Cu50Pt100/Pt200/Pt500/Pt1000/Cu10/Cu50Accuracy0.4oC0.4oCResolution0.1oC0.1oCFrequency(Hz)Range3Hz ~50KHz3Hz ~50KHzAccuracy±2words±2wordsResolution0.01Hz0.01HzFrequency(CMP)Range180~3000000 CPM180~3000000 CPMAccuracy±2words±2wordsResolution1CPM1CPMSwitchRangeCLOSE/OPENCLOSE/OPENThreshold200 ~300Ω200 ~300ΩPressureRangeDepends on the pressure moduleDepends on the pressure moduleAccuracy=±( % of Reading+ % of Range)Depends on the pressure moduleDepends on the pressure moduleResolution5 digit display5 digit displayContinuity beeperRange0 ~500Ω0 ~500ΩAccuracy≤50Ωsound≤50ΩsoundResolution0.01Ω0.01ΩLoop power supplyRange24V24VAccuracy±10%±10%The maximum current22mA22mAHART ×√Other functionsBacklight√√Auto Power-off√√Charging function√√Room temperature display√√Battery detection√√The ramp signal√√Communication functionRS232 serial communication, can realize remote control instrument by the device driver software.RS232 serial communication, can realize remote control instrument by the device driver software.CharacteristicSafetyEN61010-1:2001EN61010-1:2001Withstand voltageThe input and output AC350V/1 minutesThe input and output AC350V/1 minutesInsulationThe input and output DC500V /50MΩ.The input and output DC500V /50MΩ.EMCEN61326-1:2006EN61326-1:2006AuthenticationCECEDisplay3.2" TFT screen3.2" TFT screenPower supply4×1.5V AA Alkaline battery4×1.5V AA Alkaline batterySize206 × 97 × 60 mm206 × 97 × 60 mmWeightabout 633gabout 633gStandard Quantity Per Carton6pcs6pcsStandard Carton Measurement530mm*405mm*310mm530mm*405mm*310mmStandard Carton Cross Weight12.6kg12.6kg
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...