IPDB › China Industry › Instruments & Meters
China, Chinese Tob Glovebox for Lithium Battery1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Test InstrumentEnvironmental Test ChamberLab Glove BoxLab Vacuum Glove Box
XIAMEN TOB NEW ENERGY TECHNOLOGY CO., LTD.
Preview:
Product Description Vacuum Seal Single Station Glove Box with Flange WindowWater and oxygen content<0.1PPMLeakage rate<0.001%vol/hThe working gas is nitrogen, argon and other inert gases. The regeneration gas is a mixture of inert gas and hydrogen (hydrogen 5-10%)Traditional window VS O-ring sealing flange windowTOB-GB1220-N Single Station Glove Box with Flange windowSingle station, single operation,integrated with a single column purification unit,PLC touch screen operation control, vacuum pump, bracket, a closed box, with operating surface tilt and detachable safety glass front window. Under normal conditions, namely the 20oC constant temperature, a standard atmosphere, inert gas 99.999%, water and oxygen index less than 0.1 ppm.ItemParameterMain parameterWater/ oxygen index: Less than 0.1ppmLeakage rate : 0.001vol%/hGlove boxBoxBox size: (L*W*H)=1220×750×900mmBox material: stainless steel 304, thickness 3mmInner surface: stainless steel wire drawing treatmentOutside surface: paint, whiteFront windowTilt windows, transparent tempered safety glass, thickness 8 mmThe glass window adopts a solid O-ring (vacuum sealing method) flange window structure.Glove portsThe material is polyoxymethylene, O-ring seal, self-lubricating performance, easy to maintain, and good sealing performanceGlovesButyl rubber, thickness 0.4mm, diameter 8", length 32"Filter:0.3 microns, a gas inlet and a gas outletShelfStainless steel, 2-3LayersLightingLED lights, installed in front of each glass windowConnectorStandby interface 4pcs, DN 40 KF, Power interface 1pc (220V)Bigger antechamberChamberSize: diameter 360mm, length 600mmMaterial: 304 stainless steelSurface: inner surface wire drawing process, outer surface painting (white)AccessorySliding tray: 304 stainless steelDoor: double door, anodized aluminum material, thickness 10mm, vertical operation, with lifting mechanismPressure gauge: Analog displayControlSolenoid valve touch screen automatic operationSmaller antechamberChamberSize: diameter 150mm, length 300mm (100mm length into the glove box)Material: 304 stainless steelSurface: inner: wire drawing process, outer: painting (white)AccessoryStandard configuration: small cabin trayDoor: double door, thread lockPressure gauge: Analog displayControlManual valve manual operationGas purification circulation systemPurification columnFunction: gas sealed, remove water, remove oxygenContainer material: 304 stainless steelPurification materials: copper catalyst: 5kg, molecular sieve: 5 kgPurification capacity: oxygen: 60L, water: 2KgWater and oxygen indicators: less than 1ppmCirculatory systemWorking gas: nitrogen, argon,heliumRecycling capacity: integrated fan flow 90m3 / h, install frequency conversionRegenerationOperation: PLC automatically controls the regeneration processRegeneration gas: working gas mixed with hydrogen gas, (hydrogen 5-10%)Vacuum pump12m3 / h, rotary vane pump, with oil mist filter, air vibration controlValvesMain valve: DN 40 KF, electrically operated angle valveControl valve: electromagnetic integrated valveControl SystemFunctionIncluding self-diagnosis, power-off self-starting characteristics, with pressure control and adaptive functionAutomatic control, cycle control, password protectionPressure controlPLC Auto control, cabinet working pressure +/- 15mbar can be set freely, beyond +/- 16mbar system automatic protectionPedalControl the box pressure, easy to operate boost and buckDisplay systemUsing Siemens PLC touch screen, display running status, box pressure, system records etcVacuum system controlVacuum pump, can be manually or through the PLC to start, flow 12m3/h, vacuum of the transition chamber, and keep the box pressure balance, vacuum pump limit vacuum ≤ 2x10-1pa BasiccomponentsWater analyzerMeasuring range: 0~500ppm platinum electrode structure (P2O5 structure, can reach the factory level by simple cleaning), a wide range of applications, especially for users such as lithium battery manufacturing and metal organic, can be restored to the initial state through the cleaning and regeneration process, avoiding one-time pollution and scrapping The problem.Oxygen analyzerMeasuring range: 0 ~ 1000ppmThe use of ZrO2 sensor, to avoid the fuel cell life is short, and avoid the problem of it can not be exposed in the airQuick change organic solvent adsorb-erSize: diameter 238mm, height 407mm,3mm thickness304 stainless steel Filled with 10kg of activated carbon. Connected with the main circulation pipeline, the circulating gas can first flow through the organic solvent adsorb-er device to absorb the organic solvent in the gas. Quick and convenient replacement of adsorbent materials. After replacing the activated carbon, the adsorption column can be vacuumed to eliminate air and avoid contaminating the high-purity atmosphere inside the box.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...