Send

Food Packaging Bag

Gift Box & Bag

Industrial Packaging Bag

Logistics Packaging

Machinery for Packaging Supplies

Non Woven Bag

Other Bags & Cases

Package & Conveyance

Package & Printing Service

Packaging Bags

Packaging Materials

Packing Bottle

Packing Machinery

Post-Press Equipment

Pre-Press Equipment

Printing Machinery

Printing Materials

Shopping Bags

Specialized Case & Box

Stencil

Tag & Sign

Tag Gun

Tool Packaging

Watch Box

IPDBChina IndustryInstruments & Meters



China, Chinese Smart Differential Pressure Sensor with 4-20mA LCD Pressure Transmitters Sensor1 Industrial Products Supplier Manufacturer Details, price list catalog:

China Industrial Products Supplier Manufacturer List Catalog
« Previous Next »

SensorPressure SensorPressure TransmittersPressure Transmitter

Hebei Xukang Meter Manufacturing Co., Ltd.

Preview:

Product Description Pressure sensor- manufactured from Tianjin U-ideal instrument Co., Ltd, we have pressure switch, pressure transmitter, pressure gauge, pressure sensor, capacitance pressure sensor, DP pressure transmitter.....inductive pressure sensor, piezoresistive pressure sensor, semiconductor strain gauge pressure sensor, resistance strain gauge pressure sensorPressure based transmitter Main products:Pressure transmittern  T20 series pressure transmitter/pressure sensorn  T51GP pressure transmittern  T61GP pressure transmitter/pressure sensorn  T61TGP pressure transmittern  T61AP absolute pressure transmitterDifferential Pressure transmittern  T51DP Differential pressure transmitter / pressure sensorn  T51HP high hydrostatic differential pressure transmittern  T51DR micro differential pressure transmittern  T51DP/GP remote sensor differential pressure transmittern  T61DP differential pressure transmittern  T61HP high hydrostatic differential pressure transmittern  T61DR micro pressure transmitter / pressure sensorn  T61Cn  T61DP/GP remote sensor differential pressure transmitterLiquid Level Transmittern T20L drop-in cable level transmittern T20L insert rod type level transmittern T20Y flanged level transmittern T20D press-guiding level transmittern T20M diaphragm level transmittern T51LT flanged level transmittern T61LT flanged level transmittern T61Y pressure vessel level transmittern T61W sanitary type pressure sensorFlow Transmittern T51 flow transmittern T61 flow transmittern T61S flow transmittern T61C flow transmitter UI-P61 Series Capacitance type intelligent transmitter UI - P61 Ordinary structure differential pressure, gage pressure and absolute pressure transmitterl   Accuracy 0.1%; Ratio: 50:1l   Measure pressure Range from 100 Pa to 40 MPal   Process isolation diaphragm: 316L stainless steel, Hastelloy, tantalum, Monel or 316L lined with PTFE.l   Light, small, easy to install   UI - P61C Integrated structure differential pressure, gage pressure and absolute pressure transmitterl   Accuracy 0.1%; Ratio: 50:1l   Measure pressure Range from 100 Pa to 40 MPal   Process isolation diaphragm: 316L stainless steel, Hastelloy, tantalum, Monel or 316L lined with PTFE.l   Flanged integrated structure, Good design is durable, no leakage;l   Light, small, easy to install    UI-P61T Directly mount gauge pressure, absolute pressure transmitterl   Accuracy 0.1%; Ratio: 50:1l   Measure pressure Range from 100 Pa to 40 MPal   Process isolation diaphragm: 316L stainless steel, Hastelloy, tantalum, Monel.l   Light, small, easy to install; UI-P61 LT Level transmitterl   Accuracy 0.2%; Ratio: 15:1l   Flat diaphragm or 50mm, 100mm, 150mm, 200mm inset diaphragm.l   Various filling liquid to suit strict temperature.l   Process isolation diaphragm: 316L stainless steel, Hastelloy, tantalum, Monel or 316L lined with PTFE. UI-P61 Remote pressure /differential pressure transmitterl   Accuracy 0.2%; Ratio: 15:1l   Flat diaphragm or 50mm, 100mm, 150mm, 200mm inset diaphragm.l   Suit stricter temperature.l   Process isolation diaphragm: 316L stainless steel, Hastelloy, tantalum, Monel or 316L lined with PTFE. UI-P61W sanitary pressure transmitterl   Accuracy 0.2%; Range ratio: 15:1l   Various process mounting type..l   Various filling liquid to suit various sanitary conditions.l   Process isolation diaphragm: 316L stainless steel, Hastelloy, tantalum, Monel or 316L lined with PTFE.   UI-P61Y pressurized container special using drop-in type level transmitterAccuracy 0.2%; Range ratio: 15:1Various process mounting type.Various filling liquid to suit strict temperature.Process isolation diaphragm: 316L stainless steel, Hastelloy, tantalum, Monel or 316L lined with PTFE.U-ideal′s 3351(&1151) 3051DP differential pressure transmitter provides a kind of reliable measuring way. It is used for measuring differential pressure (or pressure), level, density of liquid, gas or steam and convert the value of above into current signal output or digital protocol output. The pressures are directly applied to the isolating diaphragm that provide isolation and resistance against process fluid corrosion. Being microprocessor based, the electronic circuit is extremely versatile and accurate. Combined with the sensor precision, it provides the high accuracy and range ability. Transmitter performance is improved by continuous monitoring of the sensor temperature and corresponding corrections. A local display permits easy reading and writing of data. The Model 3351 design is offered for Differential Pressure (DP), Gage Pressure (GP) and Absolute Pressure (AP) measurements. The Model 3351utilizes capacitance sensor technology for DP measurements. The major components of the Model 3351 is the sensor module and the electronics housing.  TECHNICAL SPECIFICATIONSSuper measuring performance, used for pressure, differential pressure, liquid level, flow measure, High accuracy: digital accuracy + (-) 0.05%; Simulation accuracy + (-)0.5% +-~ 0.1% F.S range.Zero and span external continuous adjustable; range: 100:1.Positive transfer up to 500%, negative transfer to 600%.Stable performance, stability: 0.25% 60 months.Overpressure resistant.Solid sensor design.A full serious of unified structure, strong interchangeability.Optional contact medium diaphragm material.Low pressure casting aluminum alloy shell.Measuring rate: 0.2 s. Connection is compatible with other products, to achieve the best measurement.Adopt 16 computer intelligent transmitters.Standard 4-20 mA, a digital signal based on HART protocol, remote control.   Parameters Using object: liquid, gas and steam; Power supply voltage: 12 ~ 36 v DC, standard 24 VDC; Output signals: 4 ~ 20 mA DC; ( 4-wire 220V AC power supply 0 ~ 10 mA DC output special)Ambient temperature: 25 ~ 70 oC (transmitter), 15 ~ 70 oC (with the indicator). Measure temperature: - 40-104 oC, flange pump silicone oil filling - 40-104 oC, high temperature silicone oil filling 15-315 oC.Storage temperature: - 40 ~ 100 oC; Relative humidity: 0-100% RH, Protection grade: d II BT4, ia II CT5; Power effect: less than the output range of +/- 0.005% / V; Vibration: vibration 200 Hz in any direction, the error is to 0.05% of the maximum range/g (micro differential pressure is 0.25%/g); Installation location effect: when the work diaphragm is vertical installation, may be no greater than 0.24 Pa zero error, error can be eliminated by adjusting the zero, won't impact range; Stability: six months less than the precision of the transducer; Indicator: linear indication 0 ~ 100%; 3-1/2 LCD.Range and zero: external continuous adjustablePositive and negative migration: the most-positive migration amount was 500%, the largest amount of negative transfer of 600%Material : Isolation diaphragm: 316 SS, Hartz-C type alloy, monel alloy, TantalumVent/drain valve: 316L stainless steel, ha - C type alloy, monel alloyFlange and fittings: 316L stainless steel, Hartz - C type alloy, monel alloy"O" type circle: fluorine rubberInert filling liquid: silicone oilBolt: 316L stainless steelElectronic shell: low copper aluminum alloy  ModelTransmitter Type(Single selection)DPHPGPAP3051DPDifferential Pressure transmitter.---3051HP High pressure Differential pressure transmitter-.--UIP-T62GPGauge Pressure--.-3051AP Absolute Pressure---.CodePressure Measure range(URL)(Single selection)DPHPGPAP31.3~7.5kPa...-46.2-37.4kPa....531.1-186.8kPa....6117-690kPa....7345-2068kPa....81170~6890kPa.-..93480~20680kPa--.-06890~41370kPa--.-CodeTransmitter output (single selection)DPHPGPAPE 4-20mA,Linear, Analog /damping adjustable....N 4-20mA, digit intelligent type....S4-20mA,intelligent, HART protocal....Codeflange & Jointsdrain/ventdiaphragmDPHPGPAP22316SS316SS316L SS....23316SS316SShastelloy C....24316SS316SSMonel Alloy....25316SS316SStantalum....33hastelloy Chastelloy Chastelloy C....35hastelloy Chastelloy Ctantalum....44Monel AlloyMonel AlloyMonel Alloy....CodeIndicator (If don't need local display, don't select)DPHPGPAPM1 Analog Scale, Linear head, 0-100% scale....M2Analog Scale, square root      showing, 0~10 scale..--M3 LCD, linear head, 0-100% selectable....CodeMounting bracketDPHPGPAPB1Tube bending plate ( tube outside diameter Φ50~60)....B2Plate bending plate....B3Tube flat plate ( tube outside diameter Φ50~60)....CodeRelease valveDPHPGPAPD0Drain valve at the back....D1Side Release valve above the pressure chamber....D2Side Drain valve at the bottom of the pressure chamber....CodeLow pressure side Flange adaptorDPHPGPAPN no flange adapter (with 1/4NPT female at flange to connect the press-leading lines)....C1 1/2NPT female screw flange adapter, connect pilot pressure joint and welding press-leading tube(stainless steel) ....C2 M20x 1.5 Male screw flange adapter, connect pilot pressure joint and welding press-leading tube(stainless steel)....CodeExplosion-proof (don't select is standard type)DPHPGPAPd explosion-proof Exd II CT6....iIntrinsically safety Exia II CT6....Typical model:  3051DP 4 S 22 M3 B3 D2 C2Performance & technique parameter (Reference conditions: no zero migration, silicone oil filling, 316L diaphragm)The output signal: 4-20 mA two-wire system;Accuracy: Linear output: ±0.1% (to range ratio 1:1}, including linear, variation, the repeatability general error.Extraction of root output: when the output pressure is 4-100%, is (0.2% of Calibrated range + 0.05% at biggest).Stability: for DP range code 3, 4, 5, stability is ±0.2% of the highest range. For other range code, stability is ±0.25% of the highest range.Humidity: 0-100% relative humidity;Start time: At minimum damping, 2 seconds at most.Volume drain: <0.16 cm3Damping: electrical damping is 0 to 32s. In addition, the sensitive element have 0.2s Constant damping time (range 3 is with 0.4 seconds);Static pressure effect (DP transmitter)Zero error: If 10 Mpa, zero error is 0.25% of the highest range; for range which code is 3, zero erro is 0.5% of the highest range; zero point can be corrected through the zero adjustment.Temperature influence:The zero error at the biggest range:±0.5% every 56 oC; total influence include span and zero error, ±1% every 56 oC; for range which code is 3 in model table, the influence is times of above range;For the smallest measure range zero error, ±0.5% every 56 oC; total influence include span and zero error, ±3.5% every 56 oC; for range code 3 in model selection, the influence is times of above range;Vibration impact: Frequency is o - 200 HZ, each g is ±0.05% up limit at any direction.Power supply: < 0.005%/V of calibration range.Installation position influence: zero drift <0.25 KPa, the error can be eliminated by correction, so without impact to range.Electromagnetic interference/radio frequency interference: according to SAMA PMC33.1, test from 20-1000 Hz, field intensity can be up to 30V/m.Standard structureWet parts materialsIsolation diaphragm316L, Hastelloy C - 276, monel or tantalum, each types optional materials, see to the order information table.Drain/air valve316L, Hastelloy C - 276, monel. Each type optional material, see to the order information table.Wet O-rings: Non-wet parts material:Liquid filling: Silicon or Inertia fluidBolts and flange with bolts: galvanized carbon steel;Electric shell: Low copper aluminum;Spraying: polyurethane (PU)Gauge cover O ring: NBR (nitrile rubber Buna)Process connection port:1/4 ~ 18 NPT: Range 3, 4 and 5, flange distance: 54 mm1/4 ~ 18 NPT: Range 6 and 7, flange center distance: 56 mm1/4 ~ 18 NPT: Range 8, flange center distance: 57 mmRange 3, 4 and 5, Flange joint can be rotated, in order to realize the 51 mm,54 mm or 57 mm center distance.Electrical connections 1/2~14 NPT or M20X1. 5 conduit entrance; weight: 2.4 kgConditions of useOverall protective performance: IP67Power supply voltage:12V - 45VDC intrinsic safety products, power supply should through safety barrier firstly. (Standard is 24 VDC, if no load can work at 12VDC, with LCD header power should be not less than 16 VDC)Products application environmentTemperature: - 20oC~+80oC, storage temperature: - 40oC - + 104oC; humidity: 0-90%Explosion-proof products using environmental conditions:Temperature: - 20oC - + 40oC; relative humidity: 5% ~ 95%.Atmospheric pressure: 86-106 KPaIntrinsic safety production matched safety barrier parameters:Uo ≤28r DC; Io≤30mA   UI-P61 series intelligent pressure / differential pressure transmitterGeneral introduction:Application:UI-P61 series pressure/ differential pressure transmitter have many different types which are used to measure differential pressure, flow, gauge pressure, absolute pressure, vacuum degree, liquid level and specific gravity. Read carefully the order instruction table to confirm us the transmitter model, pressure range, signal output type and transmitter's structure materials. Working principle:When work, the high and low pressure side diaphragm and filling liquid pass the pressure to the center of filled liquid, the center filled liquid passed the pressure to center diaphragm ofδchamber sensor, and the sensing diaphragm is a tension elastic element, the displacement changed by the differential pressure ( GP gauge pressure transmitter, atmospheric pressure is like exert the pressure on the low pressure side of the sensing diaphragm; AP absolute pressure transducer, low pressure side always keep a reference pressure). The largest displacement of diaphragm is 0.1 mm, and the displacement is proportional to the pressure force. The capacitor plate on both sides sense the diaphragm position. The differential capacitance value between Sensing diaphragm and electrical capacitor plate is transferred into the corresponding current, voltage or digital HART output signal.PCB moduleThe transmitter PCB module adopts special using Integrated Circuit (ASICS) and surface sealing technology. When the PCB received the digital signal from sensor diaphragm and coefficient corrected correct the signal and linearizing it. PCB output the digital signal to analog signal output and communicate with Hart operator. Is insert the LCD head to the PCB, then the transmitter can display the pressure unit and percentage unit digital output.The data configurationThe configuration data stored n the transmitter circuit board EEPRQM permanent storage. So the Transmitter still can save the data even power off. Therefore the transmitter can work immediately once power on.Digital / Analog converter and signal transmissionProcess Variable is stored by data mode. Can be fine corrected and engineering unit converting. Then the corrected data is converted into analog signal output. The HART operator can store the sensor digital signal directly with higher accuracy which don't need digital / analog converting again.Software function:HART protocol make user easily to configure, test and set the UI-P61 series transmitter.Communication ModeUI-P61 series pressure/differential pressure transmitter adopts HART protocol communication.The protocol adopts the industrial standard Bell202 frequency shift keying (FSK) technology, superimposed a high frequency signal on the current output signal to realize the remote communication. This technology can make the transmitter communication and output at the same time and without influence the Loop consistency.The configurationUI-P61 series pressure/differential pressure transmitter can be easily configured with HART hand operator. The configuration includes two Aspects. First. The transmitter operational parameter Settings, include Settings:l   Zero and span setl   Linear output or square root outputl   Damping,l   The engineer unit selectionThe second, the informational data of transmitter deposited in the transmitter which to recognize the transmitter and make physical description for the transmitter. These data include:l   Location number: 8 letters, number and charactersl   Descriptors: 16 letters, number and charactersl   Information: 32 letters, number and charactersl   Date & integrated transmitter head installationl   Flange type, and flange materiall   Drainage/exhaust valve materials & O ring materiall   The remote parts material informationIn addition to the above, the software also contains many non users can modify information: the transmitter types, sensor limited, the minimum range, filling liquid,  the diaphragm material, diaphragm head serial number and software version number. TestUI - P61 series pressure/differential pressure transmitter can do self-inspection consecutively. If problems found, transmitter will activate the users optional analog output alarm, can check the problem with HART hands operator to determine the problem. Transmitter output specific information to the HART operator to help identifying the problem and maintenance immediately. If the operating personal convinced that the problem is come from circuit return, the transmitter can provide the specific output by asking which is for use of loop test.The specific SettingsSpecific Settings for transmitter first time setting and the digital PCB maintenance. It allows fine adjustment to the sensor and the analog output to meet factory pressure standards. In addition, the characteristic function avoid the user accidental or intentional adjusting the setting point of analog output. Technique informationMedium: Liquid, air or SteamOutput: 4~20mA DC, user can select linearity or square root output digital process variables added to 4~20mA signal. Are available on the HART protocol used on microcomputer.Power supplyRequire outer power supply. Working power is 12~45VDC when transmitter without load.  VminVmaxRminRmaxRL at Power Vs12V45V0'Ω1650'ΩR1=(Vs-12)/0.02   Span and ZeroCan adjust the Span and Zero through the transmitter or by HART operator remote adjustment.Zero positive and negative shiftWhen Zero negative shift, the range low limit must be ≥- URL;The zero positive shift must be ≤+ URL.Test range must ≥the minimum span.Temperature limitPCB operating temperature: -40 to 80o;  The sensor working temperature: filling silicone oil: -40 to 104oC Filling liquidTemperatureSpecific gravityg/cmcoefficient ofthermal expansionviscosityat 25oC200# silicon-40~149oC0.9340.001089.5high temperature silicon oil15~315oC1.070.0005344Inertia oil-45~205oC1.850.00086465 Humidity limit: 0~100% relative humidityVolume changing: <0.16cm3Fault alertSelf-diagnostic function detected the transmitter failure, then analog signal is output by lower than 3.9mA or higher than 21mA to alert user. The high or low alarm signal can be selected by user. Electric Level4~20mA saturation value4~20mA alert valvelow3.9mA3.8mAhigh20.8mA21.72mA Transmitter protectionUse transmitter protection function can prevent changes the transmitter configuration, including preventing the device zero and span adjustment. Protect function can be set by internal switch.Over voltage alarmIf the transmitter output a negative overvoltage, then the analog signal output 3.9mA; If the transmitter output an positive over voltage value, the analog signal output 20.8mA.DampingSilicone oil filling at room temperature, the electrical damping is 0~32seconds.The smallest time constant is 0.1 seconds (range 3 is 0.4 seconds).High temperature silicone oil filling transmitter, this value will be higher.Performance parameter(The zero base calibration range, reference conditions, silicone oil filling, 316L isolation diaphragm)Accuracy (including linear, variation, repeatability total error)Range code from 4 to 8, DP and GP transmitter; Range code 4 to 7, HP transmitter±0.1% of calibration range;±0.1%+ (0.01range high limit / range)% (more than 10:1 range ratio).Other range and model transmitter ±0.25% of calibration rangeThe stabilityDP and GP model, the range mode 4 to 8: ±0.1% URL, 12 months;Other range and model transmitter: 0.25% URL, 12 months. Temperature influence:DP and GP transmitter, measure range code from 4~8;HP transmitter, measure range code from 4~7.Zero error=±0.2% URL/56oCTotal error=±(0.2% URL+0.18% calibration range)/56oCOther measure range and model transmitter the temperature influence times higher. Static pressure influenceDP series transmitterZero errorFor measure range code from 4~8, at 10 Mpa, zero error is ±0.25% URL; for measure range code is3, the error ±0.5%URL; zero error can be corrected through the zero adjustment on line.Span errorCan be corrected to ±0.25% of input reading value / 6.8MPaFor measure range code is 3, the span error can adjusted to ±0.5%. HP (high pressure) transmitterZero errorAt 32Mpa static pressure, zero error is ±1% URL; Zero error can be corrected through the zero adjustment on line.Span errorCan be corrected to ±0.25% of input reading value / 6.8MPa Vibration impact: Frequency which is less than 200 HZ, the impact is ±0.05% URU/g at any direction.Power impact: < 0.005%/V output range / volt.Electromagnetic interference/radio frequency interference: according to SAMA PMC33.1, test from 20-1000 MHz, field intensity can be up to 30V/m, the output shift is less than 0.1% of span.Installation position influence: zero drift <0.25 KPa,When the liquid level diaphragm vertical mounting the zero drift is less than 0.25KPa,when the liquid level diaphragm is horizontal installing the zero drift is less than 1.25KPa which plus the extended part length.All the error can be eliminated by correction on line, so won't impact to range. Structure specifications:Wet parts materialsIsolation diaphragm 316L, Hastelloy C, monel or tantalum.Drain/air valve 316L, Hastelloy C, monel.Wet O-rings:  NBR, PTFE or metal sealing ring.Non-wet parts material:Liquid filling: Silicon or Inertia fluidBolts and flange with bolts: galvanized carbon steel or 316SS;Electric shell: Low copper aluminum;Spraying: polyurethane (PU)Gauge cover O ring: NBR (nitrile rubber Buna)Process connection port:1/4 ~ 18 NPT: Range 2~ 5, flange distance: 54 mm1/4 ~ 18 NPT: Range 6 and 7, flange center distance: 56 mm1/4 ~ 18 NPT: Range 8, flange center distance: 57 mmRange code 2~ 5, Flange joint can be rotated, in order to realize the 50.8 mm,54 mm or 57.2mm center distance.Electrical connections 1/2~14 NPT or M20X1. 5 conduit entrance; with bolts endsExplosion-proof class: explosion-proof Exd II BT6 or intrinsically safety Exia II ct4Weight: if don't include accessories, the AP, DP, GP, HP models weight is 2.4kg.Power supply voltage:12V - 45VDC intrinsic safety products, power supply should through safety barrier firstly. (Standard is 24 VDC, if no load can work at 12VDC, with LCD header power should be not less than 16 VDC)Products application environmentTemperature: - 20oC~+80oC, storage temperature: - 40oC - + 104oC; humidity: 0-100%Explosion-proof products using environmental conditions:Temperature: - 20oC - + 70oC; relative humidity: 5% ~ 95%.Atmospheric pressure: 86-106 KPaOur companyPackaging & Shipping

Link supplier or manufacturer »

Instruments & Meters: Smart Differential Pressure Sensor with 4-20mA LCD Pressure Transmitters Sensor
Inscinstech Protein Purification System (Unique AutoPure300) Protein Purification Techniques1603byte
ID200*650 Preparative Purify HPLC System1844byte
Fps-100c Single Channel Automatic Peptide Synthesizer1323byte
Inscinstech Lab Instrument Automatic Large Scale Oligonucleotide Synthesizer (Unique AutoOligo25) for The Rapid Synthesis of 10~100μ Mol Nucleic Acid Samples648byte
ID1400*500mm Auto Acrylic Column Column, Bed Lenght 500mm1439byte

ID600mm Purify HPLC System for Natural Plant1537byte
Inscinstech Automatic Large Scale Oligonucleotide Synthesizer (Unique AutoOligo100) for The Rapid Synthesis of 50 μ Mol-9 Mmol Nucleic Acid Samples640byte
Factory Price HPLC High Performance Liquid Chromatography with Isocratic And Gradient System2545byte
Chromatographic Columns USP L1 L8 L11 L10 L Ods Cn C18 C8 Normal Phase / Reverse Phase HPLC Column4416byte
Inscinstech Lab Instrument Protein Purification System (Unique AutoPure150-L1) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP822byte

50dac Preparative Purify HPLC System2241byte
High Efficiency One Stop Solution Chromatograph Machine HPLC Systems High Performance Liquid HPLC Chromatography2545byte
Laboratory High Performance Liquid Chromatography Machine HPLC Chromatography LC-W100A2771byte
LC Laboratory High Performance Liquid Chromatography HPLC with UV Detector for Food Analysis7365byte
100ml Fplc Chromatography for Cetuximab1701byte

Inscinstech Ion Chromatography Protein Purification System (Unique AutoPure25-L1) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP811byte
Biobase HPLC High Performance Liquid Chromatography System Gas Chromatograph5402byte
Biobase Eclassical 3100 Laboratory High Performance Liquid Chromatography System for Laboratory HPLC1278byte
Mass Spectrometer Gas Chromatograph with Fid Detector4942byte
Dw-Gc1120 Economic Gc System Gas Chromatography Fid Tcd Ecd Npd Lab Gas Chromatograph Machine3011byte

High Accuracy Transformer Oil Gas Analyzers Price Dissolved Gas Analysis Equipment GC MS Insulating Oil Gas Chromatograph3258byte
SCITEK Gas Chromatograph Self-Diagnostic System Chromatograph With Seamless PC Control3341byte
Explosion Proof Real-Time Industrial Online Process Analyzer Industrial Online Gas Chromatograph4030byte
Double Beam UV-Vis Spectrophotometer / Spectroscopy Instrument1546byte
2025 RoHS Directive Detection Edxrf Energy Dispersive X-ray Fluorescence Spectrometer2432byte

Gas Chromatograph Mass Spectrometer Gc-Ms4084byte
Laboratory High Performance Liquid Chromatography HPLC with UV Detector for Food Analysis952byte
Inscinstech Protein Purification System Lab Instrument (Unique AutoPure100-L2) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP1569byte
1000ml Ss Pump for Ion Chromatography Pump1448byte
Gc112A Lab Gas Chromatograph Analysis Instrument2874byte

Alva SPD620 Laboratory Sample Pretreatment Digestion Instrument with Metal Heating Module, Chemistry Lab Instrument7790byte
China Factory High Efficiency Kjeldahl Digestion Furnace for Lab Use2011byte
High Precision High Frequency Infrared Carbon Sulfur Analyzer for Alloy Plant5415byte
Carbon Silicon Tester for Foundries Is Used for Pre-Furnace Scarbon Silicondetection of Gray Cast Iron Ductile Cast Iron Foundry Molten Iron Testing Equipment3289byte
Unparalleled Accuracy in Carbon Sulfur Testing with Our Superior Technology Xrf ACP Aas Manufacture6697byte

Aurispec P3 Xrf, Portable Analyzer, Gold Tester, Spectrometer1348byte
Automatic Fat Analyzer SD-P6s for Measuring Fats and Other Compounds Using The Soxhlet Extraction Principle8780byte
Sequential Inductively Coupled Plasma Emission Spectrometer-Icp-Oes/Icp-AES 5% off1756byte
Automatic Kjeldahl Nitrogen Analyzer for Food Crops and Feeds2445byte
High Precision Portable Chlorophyll Meter3412byte

High Precision and Speed with Mining Steel Carbon Sulfur Analyzer6697byte
Digital Oxygen Nitrogen Hydrogen Analyzer for The Determination of Steel1896byte
Aurispec B6t, Benchtop Xrf, Coating Thickness Analyzer, Element Analyzer, Soil, Spectrometer2421byte
Casting Furnace Front Carbon and Silicon Analyzer Automatic Analysis and Automatic Printing5945byte
Fd6800 Fiber Analyzer: Fully Automated Chemistry Elemental Analyzer for Sensitive Detection of CF, Adf, Ndf, Cellulose, and Lignin8082byte

Nanbei Crude Protein Analysis Automatic Kjeldahl Nitrogen Analyzer5041byte
Drawell Portable Xrf Gold Tester Handheld Xrf Mineral Analyzer X-ray Fluorescence Spectrometer2331byte
CS995 High-Frequency Infrared Carbon Sulfur Analyzer for Metal Mineral Coal3201byte
Handheld Smart Mini Poct Automated Blood Gas and Electrolyte Analyzer Electrode Method Blood Analyzer for Hospital Use (SG1)1327byte
Hand-Held Pesticide Residue Meter for Food Safety Meter4150byte

Xrf Sulfur Analyzer X-ray Sulfur Analzyer 5% off1089byte
Desktop Liquid Security Detector Liquid Trace Detector695byte
High Quality Single Flame Atomic Absorption Spectrometer for Lab4823byte
Innovate High-Frequency Infrared Carbon & Sulphur Analyzer5536byte
Carbon Silicon Analyzer for Molten Iron Fast Foundry Thermal Analysis System Cup Sampling Furnace QC Testing Carbon Equivalent Measurement on-Site Liquid Metal5549byte

Full Automatic High Frequency Laboratory Equipment Analysis Instrument Testing Machine Metal Detector Chemistry Analyzer Metal Infrared Carbon Sulfur Analyzer6669byte
Semi-Auto Kjeldahl Protein Analyzer From Factory2538byte
High-Precision Kjeldahl Nitrogen Protein Measurement Equipment for Labs3768byte
Aurispec H3 Xrf, Portable Analyzer, Gold Tester, Spectrometer2229byte
ED6 Plus Liquid-Liquid Extractor: Fully Automated Chemistry Lab Instrument for Multi-Sample Extraction with Advanced Control8202byte

Portable Gas Detector The Gas Leak Detector Is Suitable for The Detection of C2h4 H2 CH3oh C4h10 C2h6o and Other Gases4250byte
Ethylene Oxide Alarm, Industrial Explosion-Proof Gas Leak Detector, Concentration Detector C2h4o Gas Detector3367byte
Quick Fuel Cell Tester LCD Screen Rapid Alcohol Breathalyzer945byte
O2 Auto Detector System 8 Channel Fixed Gas Leak Analyzer Controller2700byte
Exhaust Gas Analyzer Automotive Exhaust Gas Analyzer2840byte

Y09-310 (AC-DC) 28.3 L/Min Battery Operated Laser Particle Counter for Clean Rooms3401byte
Factory Price Shc-300 Alkaline Water Electrolysis Hydrogen Generator for Fid1955byte
Drop Wire FTTH Optical Fiber Cable 1000m/Wood1730byte
Cost-Effective Portable Oil Particle Counter Lubricant Oil Water Content Tester Online Particle Meter8434byte
High Quality Jy-Ecpt3000 Electrophoresis Power Supply with Constant-Voltage for Lab1983byte

Laboratory Acidity Alkalinity Redox Titration Benchtop Digital Automatic Potential Potentiometric Titrator2848byte
Iot Sensor3333byte
Automatic Fluoride Monitoring System for Sewage Treatment Equipment Spectrophotometry1948byte
as-300A Automatic Hall Flowmeter for Metals2041byte
Dlab Brand Laboratory Equipment Mx-T6-S Blood Roller Mixer1411byte

Metallographic Inlay Manual Model Xq-1 Metallurgical Sample Mounting Press3325byte
Alpha-610 Advanced Lab-Grade Automatic Metallographic Grinding and Polishing Machine2947byte
Quick Temperature Measurement Thermocouple for Fast Temperature Readings4468byte
Cheap Price Paper Tube Sampler Immersion Fast Response Sampler for Molten Metal5087byte
Precise Rated Type K 602 604 Measuring Thermocouple Connector Thermocouple4685byte

Factory Manufacturing Customizable Metal Immersion Disposable Iron Sampler4555byte
High Pressure Laboratory Sample Low Price Flexpress Screen Display Vacuum Automatic Metallographic Specimen Mounting Molds and Clamps Press Machine2483byte
Long - Lasting T-35K Type Armored Rapid Temperature Measurement Thermocouple4685byte
Mt-1h Automatic Hydraulic Specimen Precision Metallographic Mounting Equipment Professional Lab-Grade Sample Preparation Machines for Microscopy Analysis2510byte
High Accuracy Industrial Grade 602 604 Temperature Measuring Thermocouple4685byte






Purchasing Request


Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...

  • Professiona Secured Trading Service
  • Verified Business Licenses to Supplier or Manufacturer
  • Welcome to our Global alliance Member