IPDB › China Industry › Instruments & Meters
China, Chinese Factory Price Newest Energy Analyser Power Analyzer for Power Consumption Analysis1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Meter for ElectricityEnergy Meter Power MeterElectric Energy MeterEnergy Meter
ROGOWSKI TECHNOLOGY (SHANGHAI) CO., LTD.
Preview:
Product Description Senior product consultant Susan Mi550 Characteristics: 1 Handheld power quality analyzer2 Built-in lithium batteries3 Built-in 32GB memory4 Export data from a USB flash drive5 4 inch IPS display6 CO2 emission factor7 Support Chinese, English, multilingual display8 Communication: RJ45-Ethernet, Modbus-TCP/IP9 Data, event, 1-50 harmonic values and waveform record.10 Graphs : waveform, vector diagram and histogram display1)Power quality:Voltage swell and dip(Record time, amplitude value, voltage RMS 1/2 value of each phase and voltage waveform of each phase)2)Waveform display Ua,Ub,Uc,Ia,Ib,IcWaveform reading (UDP protocol)11 Accessories: 5pcs voltage clamp, adaptor, 5pcs magnetic probe12 The internal electric energy chip: the world's top ADE9000 chipProduct descriptionMi550 handheld three phase power quality analyzer, externally connected with open type Rogowski coil or voltage type CT, it can realize none dismantling wire test, simplify test steps, save construction cost, and is more convenient for engineering test as well as the inspection and maintenance of distribution system.Support systems of single-phase and three-phase. It can measure multiple electrical parameters such as current, voltage, power factor, power, energy, and power quality parameters including harmonic, unbalance degree, voltage swell and voltage dip, etc.In addition to the measurement function, Mi550 is equipped with various records, such as waveform records and programmable interval measurement value records. To store and record data, it is internally embedded 32 GB memory card.With standard configuration of RJ45 Ethernet communication interface, through standard Modbus TCP protocol, it is compatible with various configuration systems and could transmit the electrical parameters collected by the front end to the system data center in real time. General parametersTable 11 General parametersProduct nameModel No.Mi550TypeHandheld Three phase power quality analyzerApplication fieldApplication fieldPower analysis, Power measurement, Power quality analysisWiring modeWiring system3P4W_4CT3P4W_3CT3P3W_3CT3P3W_2CT1P2wCurrent sensorRogowski coilVoltage-output current clampVoltage accessDirect accessConnected through voltage transformerStorageTypeTF cardCapacity32GBData exportU disk export (U disk file is FAT32 system)CommunicationInterfaceRJ45- EthernetProtocolModbus-TCPPower SupplyAdapter input5VDC, 2ABatteryRechargeable lithium battery, specification 18650, 2 pcs, capacity about 4000mAhBattery purely working time≥6hBattery charging time (off state)≤5hPower saving modeThe brightness of the screen backlight is adjustable.The automatic screen off time is adjustable.DisplaySize3.97 inchTypeIPS displayResolution ratio480*800MachineryDimention215*130*60mmWeight850gEnvironmentWorking environmentTemperature-20oC~+55oC, Humidity below 90% RHStorage environmentTemperature-40oC~+70oC, Humidity below 95% RH(non-condensing)Altitude≤2kmMeasurement categoryCAT III 600VIP codeIP30 Measurement parametersTable 12 Measurement parametersReal-time measurement dataVoltagePhase voltage: Phase ABCN phase to ground voltageLine voltage: UAB, UBC, UCAVoltage peak coefficient: Phase ABCVoltage peak: Phase ABCCurrentPhase current: Phase ABCNCurrent peak coefficient: Phase ABCK Factor: Phase ABCFrequencyLine frequencyPowerActive power: Phase ABC and total Reactive power: Phase ABC and total Apparent power: Phase ABC and total Power factorPhase ABC and totalFundamental harmonic power factorPhase ABC and totalElectrical energyActive Energy: Phase ABC and total (import / export)Reactive energy: Phase ABC and total (import / export) Apparent Energy: Phase ABC and total CO2 emissionsHarmonic measurement dataVoltage harmonicsTHD (Total harmonic percentage), TOHD (Odd total harmonic percentage), TEHD (Even total harmonic percentage), phase ABC 1-50th harmonic percentage, phase ABC 1-50th harmonic voltage valueCurrent harmonicsTHD (Total harmonic percentage), TOHD (Odd total harmonic percentage), TEHD (Even total harmonic percentage), phase ABC 1- 50th harmonic percentage, phase ABC 1-50th harmonic current valueWaveformVoltage waveformPhase ABC voltage waveform or UAB, UBC, UCA line voltage waveformCurrent waveformPhase ABC current waveformPhase angleVoltag pehase anglePhase ABCCurrent pehase anglePhase ABCPhase angle between voltage and currentPhase ABCUnbalanceUnbalanceVoltage unbalance, current unbalanceDemandPower demand and peak demandPhase ABC active power and total power, phase ABC reactive power and total power, phase ABC apparent power and total powerCurrent demand and peak demandPhase ABC Parameter accuracyTable 13 Parameter accuracyParameterTypeDescriptionVoltageChannel input voltage range0-600VAC Measurement range0-600VAC Measurement accuracy0.2%CurrentChannel input voltage range0-420mVACMeasurement rangeDifferent current sensors have different measuring ranges Measurement accuracy0.2%+ Accuracy of current sensorFrequencyMeasurement range45Hz-65HzMeasurement accuracy±0.001HzPower factorMeasurement range-1-+1Measurement accuracy±0.005PowerActive power accuracy0.5%Reactive power accuracy1%Apparent power accuracy0.5%EnergyActive energy accuracy0.5%Reactive energy accuracy1%Apparent energy accuracy0.5%Record storageTable 14 Record storageData recordRecord nameSettableRecord start timeSettableRecord durationSelectableRecording intervalSettableBasic data recordPhase voltage Line voltageCurrentFrequencyPower factorFundamental harmonic power factorPower(Active, Reactive, Apparent)Active Energy (Import energy, Export energy)Reactive energy (Import energy, Export energy)Apparent EnergyVoltage harmonics (Total harmonic, odd total harmonic, even total harmonic)Current harmonics (Total harmonic, odd total harmonic, even total harmonic)Phase voltage peakPeak factor of phase voltageCurrent crest factorCurrent K factorVoltage unbalance (negative sequence, zero sequence)Current unbalance (negative sequence, zero sequence)Angle (phase voltage angle, phase current angle, angle between voltages, angle between currents, angle between voltages and currents)Max min (Phase voltage, Line voltage, Current, Frequency, Power factor, Fundamental harmonic power factor, Active power, Reactive power, Apparent power)Demand (Current, Active power, Reactive power, Apparent power)Peak Demand (Current, Active power, Reactive power, Apparent power)Voltage harmonic data recordVoltage harmonics (Total harmonic distortion THD, Odd total harmonic TOHD, Even total harmonic TEHD, 1-50th Harmonic percentage and voltage value)Current harmonic data recordCurrent harmonics (total harmonic distortion THD, Odd total harmonicTOHD, Even total harmonic TEHD, 1-50th Harmonic percentage and current value)Data storage formatCSVEvent record [[1]]Recorded dataEvent typeStart timeDurationAmplitude valueData storage formatCSVWaveform recordingRecord nameSettableRecord the start timeSettableRecord the durationSettableSampling rateSettableLogged dataPhase ABC voltage waveformPhase ABC current waveformData storage formatCSV Safety and warning notesIn order to guarantee safe operation of the transducer and to be able to make proper use of all features and functions,please read these instructions thoroughly! Safe operation can only be guaranteed if the transducer is used for the purpose it has been designed for and within the limits of the technical specifications. Ensure you get up-to-date technical information that can be found in the latest associated datasheet under Rogowski website.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...