IPDB › China Industry › Instruments & Meters
China, Chinese Xr06cx-4n1c1 Dixell Prime Cx Refrigeration Controllers1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
HeatingRefrigeration Temperature ControlThermostat Temperature ControllerDixell ControllerDixell Temperature Controller
Shenzhen Ruifujie Technology Co., Ltd.
Preview:
Product Description Xr06cx-4n1c1 Dixell Prime CX Refrigeration ControllersDixell ControllerDIGITAL CONTROLLER WITH "OFF CYCLE" DEFROSTGeneralsPower supply: 110, 230VacProbe inputsThermostat: NTCDigital inputsAlarm, start defrost, AUX, door switch, pressure switch: ConfigurableRelay outputsCompressor: 8A, 20A optionalOtherHot Key: PresentBuzzer: Optional (available only with 8A compr. Relay) The new PRIME series in CX format, is an innovative range of products that Dixell has introduced to the market for both heating and L.T., N.T. refrigeration. The CX family (32x74mm) has new functions plus an innovative and attractive design. The revolutionary introduction of 6 keys allows the user direct access to all main functions rapidly and intuitively, while the display with illuminated icons allows an instant view of the machine's status. All the instruments in CX format incorporate the latest know how and technology, both in software and hardware to ensure the highest standards of performance. Easy and intuitive installation9 - 40Vdc power supply for refrigerated trucks (for models with 8A compressor)Energy saving cycles triggered via a digital input; for example, it is possible to work at a set point that is different from the normal one in order to, for instance, accumulate cold when electric power is cheaperContinuous cycle with dedicated set; it allows the machine to work during rapid cooling cycles to achieve the right product temperatureRegulation stop by auxiliary probe (beer dispenser applications); it is possible to supervise the tube temperature, stopping the compressor when the temperature becomes too low, and restarting when the correct values have been restoredRegulation re-start with door switch alarmMax and Min temperature or HACCP functionDigital input configurable as probeVirtual probe for air on / air off application; used in multideck applications where it is important to regulate temperature using the average of 2 temperaturesDual thermostat function; is available, on demand, in applications such as white or red wine rooms where it is necessary to maintain 2 different temperaturesCondenser temperature management to prevent critical situations in the systemTTL serial connection for monitoring systems (using XJ485CX)Connection for remote display X-REP (excludes TTL)Thermostat and Controllers with " OFF CYCLE" DEFROST for Normal, Medium and Low Temperature XR10CX Thermostat with heating or cooling action.XR20CX Controller for NT with "off cycle" defrost.XR30CX Controller for NT with "off cycle" defrost and additional configurable relay.XR35CX Controller for NT with "off cycle" defrost and additional configurable relay and RS485.XR36CX 2 set point controller for NT with "off cycle" defrost; created for applications where is necessary to maintain 2 different temperature such as white/red wine rooms Controllers for Normal, Medium and Low Temperature XR40CXDigital controller for MT and LT with electrical or hot gas defrost.XR50CX Controller for MT and LT with electrical or hot gas defrost and auxiliary relay.XR56CX2 set point controller for MT and LT with electrical or hot gas defrost and auxiliary relay; created for applications where is necessary to maintain 2 different temperature such as white/red wine rooms Controllers for Medium and Low Temperature XR60CX Controller for MT and LT ventilated applications with dual humidity function on demand, this allows the user to activate or deactivate ventilation directly through keys, in order to regulate the humidity depending on the kind of product (ideal for pastry applications)XR64CX Controller for MT and LT ventilated applications with twin evaporators; normal regulation restarts only when both evaporators have reached defrost termination temperatureXR70CX Controller for MT and LT ventilated applications, with auxiliary relay and with dual humidity function on demand, this allows the user to activate or deactivate ventilation directly through keys, in order to regulate the humidity depending on the kind of product (ideal for pastry applications)XR71CXController for MT and LT ventilated applications with anti-sweat heater management; created for applications that utilize heating elements such as anti-mist or anti-freeze heaters on doors (heater elements can be actived by pushing a key or through a dedicated probe)XR72CX Controller for MT and LT ventilated applications with dual compressor managementXR75CXController for MT and LT ventilated applications with auxiliary relay, dual humidity function and RS485XR77CXController for MT and LT ventilated applications with Real time clock with RS485 FEATURESXR10CXXR20CXXR30CXXR35CXXR36CXPower supply12, 24Vac/dc,24, 110, 230Vac9 ÷40Vdc12, 24Vac/dc,24, 110, 230Vac9 ÷40Vdc12, 24Vac/dc,24, 110, 230Vac9 ÷40Vdc 24, 110, 230Vac12, 24Vac/dc,24, 110, 230Vac9 ÷40VdcDisplay : number digits± 3 d.p.± 3 d.p.± 3 d.p.± 3 d.p.± 3 d.p.Probe inputsThermostat NTC / PTCNTC / PTCNTC / PTCNTC / Pt1000 NTC / PTCThermostat 2---- NTC / PTCDefrost---NTC / Pt1000-Condenser NTC/PTC on hot keyNTC/PTC on hot keyNTC/PTC on hot key NTC / Pt1000 NTC/PTC on hot keyDigital inputsAlarm,start defrost, AUX, door switch, pressure switch, probe ConfigurableConfigurableConfigurable Configurable ConfigurableAlarm,start defrost, AUX, door switch, pressure switch--- Configurable-Relay outputsCompressor8A/20A8A/20A8A/20A8A/16A8A/20ACompressor 2, Thermostat 2----8ADefrost-----Fan-----Light or Alarm--8A8A-Anti - sweat-----OtherHot key / Programming Tool Kit outputPresentPresentPresentPresentPresentRemote display outputX - REP optionX - REP optionX - REP optionX - REP optionX - REP optionSerial outputTTLTTLTTLTTL/RS485TTLBuzzeravailable only with compressor = 8AReal time clock-- option option-FEATURESXR40CXXR50CXXR56CXPower supply12, 24Vac/dc,24, 110Vac, 230Vac9 - 40Vdc12, 24Vac/dc,24, 110Vac, 230Vac9 - 40Vdc24, 110Vac, 230Vac12, 24Vac/dc,24, 110Vac, 230Vac9 - 40Vdc24, 110Vac, 230VacDisplay : number digits± 3 d.p.± 3 d.p.± 3 d.p.± 3 d.p.± 3 d.p.Probe inputsThermostatNTC / PTCNTC / PTCNTC / PTCNTC / PTCNTC / PTCThermostat 2---NTC / PTCNTC / PTCDefrostNTC / PTCNTC / PTCNTC / PTC--CondenserNTC / PTC on hot key Digital inputAlarm,start defrost, AUX, door switch, pressure switch, probeConfigurableConfigurableConfigurableConfigurableConfigurableAlarm,start defrost, AUX, door switch, pressure switch-----Relay outputsCompressor 8A/20A8A/16A 20A 8A/16A 20ACompressor 2, Thermostat 2--- 8A 8ADefrost 8A 8A 8A--Fan-----Light or Alarm- 8A 5A 8A5AAnti - sweat-----OtherHot key / Programming Tool Kit outputPresentPresentPresentPresentPresentRemote display outputX - REP optionX - REP optionX - REP optionX - REP optionX - REP optionSerial outputTTLTTLTTLTTLTTLBuzzeravailable only with compressor = 8AReal time clock----- FEATURES XR60CXXR64CX XR70CXPower supply12, 24Vac/dc,24,110Vac,230Vac9 - 40Vdc24,110Vac, 230Vac24,110Vac, 230Vac12Vac/dc 24,110Vac, 230Vac12Vac/dc Display : number digits± 3 d.p.± 3 d.p.± 3 d.p.± 3 d.p.± 3 d.p.± 3 d.p.Probe inputsThermostatNTC / PTCNTC / PTCNTC / PTCNTC / PTCNTC / PTCNTC / PTCThermostat 2------DefrostNTC / PTCNTC / PTCNTC / PTCNTC / PTCNTC / PTCNTC / PTCDefrost 2--NTC / PTCNTC / PTC--CondenserNTC / PTC on hot keyDigital inputAlarm,start defrost, AUX, door switch, pressure switch, probeConfigurableConfigurableConfigurableConfigurableConfigurableConfigurableAlarm,start defrost, AUX, door switch, pressure switch------Relay outputsCompressor 8A/16A 20A 8A/16A 16A8A/16A 16ACompressor 2,------Thermostat 2------Defrost8A8A8A16A8A16ADefrost 2--8A16A--Fan8A5A5A16A5A16ALight or Alarm----8A16AAnti - sweat------OtherHot key / Programming Tool Kit outputPresentPresentPresentPresentPresentPresentRemote display outputX - REP optionSerial output TTLTTLTTLTTLTTLTTLBuzzeravailable only with compressor = 8AReal time clock----optionoptionFEATURES XR71CXXR72CX XR75CX XR77CXPower supply24, 110Vac, 230Vac 12Vac/dc 24, 110Vac, 230Vac 12Vac/dc 24, 110Vac, 230Vac 230VacDisplay : number digits± 3 d.p.± 3 d.p.± 3 d.p.± 3 d.p.± 3 d.p.± 3 d.p.Probe inputsThermostat NTC / PTCNTC / PTC NTC / PTC NTC / PTCNTC / Pt1000NTC / PTCThermostat 2------DefrostNTC / PTCNTC / PTCNTC / PTCNTC / PTCNTC / Pt1000NTC / PTCDefrost 2------CondenserNTC / PTC on hot keyNTC / Pt1000NTC / PTCDigital inputAlarm,start defrost, AUX, door switch, pressure switch, probe Configurable Configurable Configurable ConfigurableConfigurableConfigurableAlarm,start defrost, AUX, door switch, pressure switch----ConfigurableConfigurableRelay outputsCompressor8A/16A 16A8A/16A16A8A/16A16ACompressor 2, Thermostat 2--8A16A--Defrost8A16A8A16A8A8ADefrost 2------Fan5A16A5A16A5A5ALight or Alarm----8A8AAnti - sweat8A16A----OtherHot key / Programming Tool Kit outputPresentPresentPresentPresentPresentPresentRemote display outputX - REP optionSerial outputTTLTTLTTLTTLRS485RS485Buzzeravailable only with compressor = 8AReal time clock----option PresentHOW TO ORDERPRIME CXXR--CX-ABCDEABCDEPower SupplyInputs-BuzzerX-REP(excludes TTL output)RS485 output- Measurement unitRTC-Compressor outputConnection0 = 12Vac/dcP = PTC0NoNoNoC°CNo08AScrew1 = 12Vac/dcN = NTC1YesNoNoF°FNo120AScrew2 = 24VdcS =Pt1000 only for XR35/75CX2NoYesNoH °C heating only for XR10CXNo316AScrew3 = 9 ÷40Vdc3YesYesNo68AFaston4 = 110Vac----4NoNoYesL°F heating only for XR10CXNo720AFaston5 = 230Vac5YesNoYes816AFaston--6NoYesYesI°CYes------7YesYesYesM°FYes
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...