IPDB › China Industry › Instruments & Meters
China, Chinese Temperature Timing Unit, Control Temperature, Cool, Cooling Fans1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
HeatingRefrigeration Temperature ControlThermostat Temperature ControllerControl TemperatureCoolCooling FansTemperatureControl
Ningbo Turn-Link Network Communication Equipment Co., Ltd.
Preview:
Product Description Digital Temperature Unit I Size : 1U 19inchII Technical Parameters:Input: 150V~265VAC 47~63Hz Output: 150V~265VAC 47~63Hz 13AIII Instructions3.1 Proper working display :Real -time clock, the current temperature, fan state are showed on the display;3.2 Temperature setting status display:1. Press the "+" key to display the setting temperature of upper limit; press "-" to display the setting temperature of lower limit; 2.Pressing the "Temp" more than 3 seconds to enter modify mode of the temperature parameters, display "Set Tem" at the same time,then press "Temp" in turn display F1~F6 parameter value,and press the"+""-"key can modify the current F1~F6 parameter values.3.Once setting up completed, press the "Temp" button more than 3 seconds, return to the normal display status.Function Menu:ITEMSFUNCTIONSETTING RANGEUNITDefaultF1Upper limitF2~60oC25F2Lower limit-40~F1oC15F3Temperature calibration-5~5oC0.0F4Output protection time0~9Min3F5Exceeding temperature offset0~50oC5.0F6Exceeding temperature alarm delay time0~99Min5F1:Temperature upper limit:when the actual temperature is higher than the setting temperature alue,the fan start automatically.F2:Temperature lower limit:when the actual temperature is lower than the temperature,the fan stop.F3:Temperature calibration :When the measuring temperature value and the actual real temperature deviate,it will correct the temperature with this calibration value,in order to achieve the measurement accuracy.F4:Output protection time:When the fan start-up, it has to run continuously for this time value to stop.F5:Exceeding temperature offset:The default actual temperature value beyond the upper limit or below the lower limit temperature value.F6:Exceeding temperature alarm delay time:When the actual temperature beyond the temperature value "F1+F5",or below the temperature value "F2-F5",the delay buzzer alarm.4.Clock setting:Pressing "Time" button more than 3 secondsto enterthe state of the clock Settings, then press the "Temp" key switch in turn to set the correct time "hour", "minute", "seconds" state, press "+", "-" button to set the current clock.IV Alarm instructions:When actualtemperature is higher than set temperature F1 + F5 Value or lower than set F2 -F5.value, the alarm indicator start flashing, after the setting time "F6", the buzzer starts alerting until the temperature is adjusted to the normal temperature.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...