IPDB › China Industry › Instruments & Meters
China, Chinese Data Center Circuit Monitor1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Meter for ElectricityEnergy Meter Power MeterData Center Circuit MonitorBranch Circuit Power Meter
Jiangsu Acrel Electrical Manufacturing Co., Ltd.
Preview:
Product Description Product DescriptionWith the rapid development of data centers, the energy consumption of data centers has become more and more prominent, and the energy management and power supply and distribution design of data centers have become hot issues.An efficient and reliable data center power distribution system solution is an effective way to improve the Power Usage Effectiveness (PUE) of the data center and reduce the energy consumption of equipment.The AMC series precision power distribution monitoring solution is a complete solution designed for the power distribution monitoring requirements of the column head cabinet in the Internet Data Center (IDC).Product Parameters SpecificationAMC16Z-DDistribution SystemACMeasureBus voltage, current, active power, reactive power, power factor, active energy, reactive energy;Incoming voltage, current, 2-15th harmonic and total harmonic content;Outgoing line current 2-15th harmonic and total Harmonic content, current and power maximum demand, neutral voltage, neutral current, temperature, leakage currentBus VoltageRated Input220V ACMeasure Range40~400V ACOverloadInstantaneous voltage 2 times/30 secCurrent LoopIncoming LineCTSecondary 5ARange0~5AOutgoing LineCTPrimary 60ARange0.5~60AOverloadContinuous current 1.2 times, Instantaneous current 10 times/ 5 secFrequency45~60HzAuxiliary PowerAC85~265V / DC100V~350VMeasure Accuracythe Voltage and Current of Incoming Line0.5the Power of Incoming Line1the Voltage and Current of Outgoing Line1the Power of Outgoing Line2Consumption5VAInsulation resistance100MΩPower frequency withstand voltagePower/Input Signal between ports AC 2KV/1min 50HzEnvironmentTemperatureWorking:-15oC~+55oC Storage:-25oC~+70oCHumidityRelative humidity ≤ 93%Altitude≤2500mOutput 2 channels of Switch Value5A 250VAC/5A 30VDCInput Switch Value4-way passive dry contactZero sequence currentSecondary 0.5~5ALeakage Current10mA~1ANeutral ground voltage0.2V~20VTemperature-10oC~120oCCommunication2 channels of Modbus-RTUInstallationDIN35mm Din-railProtection levelIP20Pollution level2Electromagnetic CompatibilityAnti-static interference3 gradeImmunity to fast transient bursts3 gradeAnti-surge interference4 gradeResistant to radiofrequency electromagnetic field radiation3 gradeFunction AMC16Z-DOutgoing circuit built-in transformer, guide rail installation1-way incoming line + 21-way outgoing line full power + 21-way active switch4-channel passive DI+2DO1 channel temperature + 1 channel zero-sequence current + 1 channel leakage current1-way zero-ground voltage detection Dimension Installation InstructionsCommon faults and cause analysis1 Inaccurate measurement of the device * Check whether the wiring of voltage and current is correct and whether the incoming and outgoing lines of current input are correct; * Check whether the CT setting of the device corresponds to the CT actually used externally;2 Correct voltage and current measurement but inaccurate power measurement * Check whether the current input direction is correct; * Check whether the corresponding phase of each current loop is correct;3 Communication is abnormal *Check whether the communication cable is connected normally; * Check whether the A and B terminals of the communication are interleaved; * Check whether the address of the device is set correctly and whether the communication baud rate is set correctly; *When the multi-device communication is not normal, first try to see if the single-device communication is normal;4 Incoming line voltage, current, and power are available, but electric energy has no value *Check the CT ratio setting of the incoming lineCertifications EMCLVD After Sales Service Company ProfileAcrel Co., Ltd.[stock code: 300286.SZ] is a high-tech enterprise that integrates R&D, production, sales, and service, since its establishment, is committed to providing users with energy efficiency management and powerful security system solutions. Acrel Electric has a complete production line from cloud platform software to sensors. Acrel energy efficiency management system including substation operations and maintenance cloud platform, electricity safety management cloud platform, Environmental equipment power consumption monitoring cloud platform, prepaid management (system) cloud platform, intelligent power distribution monitoring system, power quality management system, building energy consumption management system, industrial energy control platform, leakage power monitor and control system, fire-fighting device power monitoring system, fire-proof door monitoring system, emergency lighting and evacuation indicating system, EV charger management system, data center power&environment monitoring system, smart lighting control system, IT isolation power supply system and related products.The company attaches great importance to product quality and innovation. By the end of 2018, the company has 5 trademarks, 18 invention patents, 72 utility model patents, 94 appearance patents, and 147 computer software Copyrights, and has participated in the formulation of national or industrial standards.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...