IPDB › China Industry › Instruments & Meters
China, Chinese TMAXCN Brand 60V40A Battery Tester for Primatic Cell Or Battery Pack Testing1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Test InstrumentBattery Tester60V40A Battery TesterBattery Pack Testing Machine
Xiamen Tmax Battery Equipments Limited
Preview:
Product Description 60V40A 1 Channel Battery Tester for the Power Battery/Prismatic Battery/ Battery Pack Testing System Features1.Single point independent, independent charging and discharging steps can be set for each battery test channel.2.The accuracy of the equipment is 0.05%, the data recording time is 1 s / time, the fastest is 0.1 s / time, and the stability is high.3.The software has powerful function and friendly man-machine interface.4.Four wire test interface ensures high measurement accuracy.5.Modular design concept, easy to maintain.Equipment DescriptionTMAX high precision battery test system is mainly designed for power battery / battery pack, which can meet the performance test requirements of power battery pack. The equipment has the characteristics of high power, high precision and high performance. It can charge the equipment voltage from 0 to 60 V and discharge from 60V to 5V, and charge and discharge test and capacity division of batteries with various specifications from 0 to 40A.Device ViewView size of single table (external dimension: length * width * height = 800 * 650 * 178mm) View dimension of the whole cabinet (external dimension: L * w * H = 790*950*1806mm)Product SpecificationEquipment modelUPC60V40A-01NCNumber of output channels of equipment model1CH (1 channel per device)Communication modeRJ45(Network port)Charging voltageDC 0 ~ 60V charging can be used to detect and set the voltage range, the maximum voltage is 60VDischarge voltageDC 60 ~ 5V discharge can be used to detect and set the voltage range, the maximum voltage is 60VCharging currentDC 0.02~ 40A can be used to detect and set the current range, the maximum current is 40ADischarge currentDC 0.02~ 40A can be used to detect and set the current range, the maximum current is 40AVoltage accuracy±(0.05%RD + 0.05%FS)Current accuracy±(0.05%RD + 0.05%FS)Voltage resolution1mV The minimum unit used by a device to detect or set voltageVoltage stability≤0.05%Current resolution1mA The minimum unit used by a device to detect or set currentCurrent stability≤0.05%Power output range0.5~Pmax = Vmax * ImaxInput impedance>=10 MΩInput powerAC 220 V ± 10% / 50 Hz (cabinet power supply mode: three phase five wire)Power accuracy±(0.05%RD + 0.05%FS)Current response timeWhen the current output is 40A, the hardware response time is as follows:≤50msTime setting rangeAny setting within 0-9999 minutes, the time units are h, min and s, and the resolution is 0.1sTime accuracy≤±0.1%Recording methodCharging recording time, discharging recording time, static recording time and global recording timeRecording frequency100mS~65535SSampling frequencyAbout 10ms per boxCharging modeConstant current and voltage limiting, constant current and constant voltage, constant power charging, constant flow charging test (battery with protection board)Charging cut-off conditionsVoltage, current, time, capacity, temperatureDischarge modeConstant current and constant power discharge (battery with protection board)Discharge cut-off conditionsVoltage, current, time, capacity, temperatureProtection functionData abnormal recovery; battery reverse connection protection function;Software over-voltage, under voltage, over-current, under current and over capacity protection. The range of voltage and current protection value can be set, and prompt and record after protection;Number of single cycle work steps≤100 steps, with nested loop functionContinuous working hoursThe power of the equipment shall meet the requirements of full load and 365 * 24-hour uninterrupted operation of all channelsEquipment noiseLess than 60dBCircuit structureModular structure design, easy to replace and maintainVCELL,TCELLAuxiliary temperature and voltage can be selected and 16 channels in single box can be selected SoftwareThe software supports various kinds of connection, such as manual suspension connection, software shutdown connection, power interruption connection, equipment communication interruption connection and abnormal stop connection;It supports barcode scanning, and can scan one-dimensional code and two-dimensional code. There are scanning methods such as sequential scanning, channel skipping scanning, loading and disk scanning;Local test detailed data storage, you can view the current test data and historical data of each channel at any time. There are two ways to display the corresponding data and curve. It also supports the export of excel report in single or batch form. In addition, it can set the automatic data export after the test according to the needs.It supports capacity sorting and can grade sort the battery;The pass / ng results can be judged according to the specified cycle capacity, voltage and time;Support all kinds of work step protection and global voltage, current and temperature abnormal protection, and carry out abnormal alarm, support battery pack overcharge and over discharge protection test;Support channel parallel connection (optional according to equipment);Support unit conversion;Support database server background storage or MES docking;Software offline protection;The software provides free upgrades.Operating / storage temperature0oC~40oC/-10oC~50oCRelative humidity of working / storage environment≤70% RH / ≤ 80% RH (no condensation)Equipment maintenanceNon professionals are not allowed to open the case. Check the equipment joint regularly to prevent poor contact.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...