IPDB › China Industry › Instruments & Meters
China, Chinese Chhgc Digital pH Meter Customizable OEM Laboratory Benchtop Water Tester1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Analysis InstrumentOther Analysis InstrumentsLaboratory Benchtop Water TesterWater Tester
Zhengzhou Resound Photoelectric Technology Research Institute Co., Ltd.
Preview:
Product Description OverviewDesktop Electrochemical Analyzer - Button Type (Single Parameter)DPH100 \ DEC100 \ DDO1001.High-definition resolution LCD screen, beautiful, clear and easy to operate2.Intelligent operating system, parameter setting and other functions3.Measurement value stable reminder, calibration completion reminder4.Data storage: 450 groups (number, value, unit, temperature, time)5.Data output: U disk / printer (printer optional)6.Dustproof and waterproof level: IP547.Electrode rack standard solutionDesktop Electrochemical Analyzer - Button Type (Single Parameter)ModelDPH100DEC100DDO100Measurement parameterspH/mV.°c?--mV(ORP).°C?--Cond/TDS/Sal./Res.°C-?-Dissolved oxygen DO--?PHMeasuring range(-2.00~20.00) pH?--Resolution0.1/0.01?--Accuracy±0.01pH ±1 word?--Automatic calibration points1~3 point automatic calibration?--Automatic temperature compensation(0.0~100.0)"C/(32.0~212.0)°F?--ORPMeasuring range(-1999.9-+1999.9) mV?--Resolution0.1/1?--Accuracy0.1%F.S 1 word?--ConductivityMeasuring range0~200.0mS/cm, automatic segmentation: 0~19.99uS/cm; 20.0~199.9uS/cm; 200~1999uS/cm; 2.00~19.99S/cm: 20.00~199.9mS/cm; TDS:0~100.0g/L (coefficient adjustable) Resistivity: 5.002·cm~100.0MQ·cm Salinity: 0-100ppt-?-Calibration points1 point-?-Resolution0.01/0.1/1-?-Automatic temperature compensation range(0.0~50.0)°C/(32.0~122.0)°F-?-Accuracy1.0% FS 1 word-?-Dissolved oxygen DOMeasuring range(0.00~20.00)mg/L--?Accuracy±0.30 mg/L--?Dissolved oxygen saturation(0.0~200.0)%--?Air pressure compensation: automatic(0~200.0) kPa--?Temperature compensation range(0.0~50.0)°C/(32.0~122.0)°F--?Salinity compensation: manual0~45ppt--?TemperatureMeasuring range(0.0~100.0)°C/(32.0~212.0)°F??? Measuring accuracy±0.2°C???OtherData outputU disk/printer??? Power supplyDC12V??? Instrument???D201T plastic case triple compound pH electrode?--DCON201T plastic case ATC conductivity electrode-?-DD001-2M plastic case dissolved oxygen electrode (polarographic type)--?pH buffer solution: 50mL pH4.00/6.86/9.18 1 bottle each?--Conductivity standard solution: 50mL146.6uS/1408μS/12.85mS/cm 1 bottle each-?-DDOS-01 dissolved oxygen internal solution: 30mL, 1 bottle--?DDOSC dissolved oxygen diaphragm cap: 3/set, 1 set--?Power adapter???DF01 universal electrode stand???Instruction manual??Desktop Electrochemical Analyzer - Button Type (Multi-parameter)DPC100 \ DPD100 \ DCD100 \ DPCD1001.High-definition resolution LCD screen, beautiful, clear and easy to operate2.Intelligent operating system, parameter setting and other functions3.Measurement value stability reminder, calibration completion reminder4.Data storage: 450 groups (number, value, unit, temperature, time)5.Data output: USB disk/printer (printer optional)6.Dustproof and waterproof level: IP547.Equipped with a variety of electrode racks and standard solutions, suitable for measuring various parametersDesktop Electrochemical Analyzer - Button Type (Multi-parameter)ModelDPC100DPD100 DCD100DPCD100Measurement parameterspH/mV.°C??-?mV(ORP).°C??-?Cond/TDS/Sal./Res.°C?-??Dissolved oxygen DO-???pHMeasuring range(-2.00~20.00) pH??-?Resolution0.1/0.01??-?Accuracy0.01PH ±1 word??-?Calibration points1~3 point automatic calibration??-?Automatic temperature compensation(0.0~100.0)"C/(32.0~212.0)°F??-?ORPMeasuring range(-1999.9-+1999.9)mV??--Resolution0.1/1??--Accuracy±0.1%F.S±1 word??--ConductivityMeasuring range0~200.0mS/cm, automatic segmentation: 0~19.99uS/cm; 20.0~199.9uS/cm; 200~1999uS/cm; 2.00~19.99S/cm; 20.00~199.9mS/cm; TDS:0~100.0g/L (coefficient adjustable) Resistivity: 5.00Q·cm~100.0MQ·cm Salinity: 0-100ppt?-??Conductivity1 point?-??Calibration point resolution0.01/0.1/1?-??Automatic temperature compensation range(0.0~50.0)°C/(32.0~122.0)°F?-??Accuracy±1.0% FS±1 character?-??Dissolved oxygen DOMeasuring range(0.00~20.00) mg/L-???Accuracy±0.30 mg/L-???Dissolved oxygen saturation(0.0~200.0)%-???Air pressure compensation: automatic(0~200.0) kPa-???Automatic temperature compensation range(0.0~50.0)°C/(32.0~122.0)°F-???Salinity compensation: manual0~45ppt-???TemperatureMeasuring range(0.0~100.0)°C/(32.0~212.0)°F???? Measuring accuracy±0.2°C????OtherData outputUSB flash drive/printer???? Power supplyDC12V????Standard packageInstrument????D201T plastic case triple compound pH electrode??-?DCON201T plastic case ATC conductivity electrode?-??DD001-2M plastic case dissolved oxygen electrode (polarographic type)-???pH buffer solution: 50mL pH4.00/6.86/9.18 1 bottle each??-?Conductivity standard solution: 50mL146.6μS/1408μS/12.85mS/cm 1 bottle each?-??DDOS-01 dissolved oxygen internal solution: 30mL, 1 bottle-???DDOSC dissolved oxygen diaphragm cap: 3/set, 1 set-???Power adapter????DF01 universal electrode stand????Instruction manual???Resound Photoelectric Technology Research Institute (LSRPTR)Resound Photoelectric Technology Research Institute (LSRPTR), also known as Resound Research Institute, is affiliated with China Haiheng International Trade Group Co., Ltd. (CHHGC). As an investment attraction enterprise in Zhongyuan Science and Technology City and a construction unit of the Zhongyuan Aurora Laboratory, the institute is committed to the industrialization of scientific and technological achievements, guided by market demand. Technical CooperationResound Research Institute has established technical cooperation with numerous well-known domestic and foreign universities, research institutes, and enterprise platforms, including: Tsinghua UniversityLanzhou UniversityZhengzhou UniversityAltai State Technical University of RussiaNorthwestern Polytechnical UniversityChinese Academy of EngineeringHenan Academy of SciencesChina Electronics Technology GroupCGN GroupXiamen UniversityHenan UniversityNational UniversityUniversity of Electronic Science and Technology of ChinaChinese Academy of SciencesChina Academy of Engineering PhysicsChina Shipbuilding GroupChina Electronics GroupHenan Inspection Group Research and Development Fields* Applications of Micro-Electromechanical and Lithography Technology* Optoelectronics and Spectroscopy Technology* High-Power Laser and Device Preparation Technology* Nuclear Instrument and Emergency Equipment System Applications Introducing Advanced Technologies and ProductsResound Research Institute continuously introduces advanced new technologies and products in industrial application scenarios such as market supervision, public safety, environmental monitoring, and science, education, research, and production. This has led to the formation of a domestically produced high-end scientific equipment industry base that integrates design, research anddevelopment, production, sales, and services. This base drives the iteration of downstream industry technology, enhances the transformation and industrialization level of scientific and technological achievements, and provides technological sources for innovative development.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...