IPDB › China Industry › Instruments & Meters
China, Chinese TH0410 high frequency coaxial shunt nominal input current 20mA ~ 10A voltage 1V1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Electronic InstrumentCalibratorCoaxial ShuntCurrent Shunt
Tunkia Co., Ltd.
Preview:
Product Description 1. SummaryTH0410 is a set of nine precision AC/DC shunts of different ranges that convert a nominal input current of 20 mA ~ 1 0 A to 1 V Small voltage, easy to access voltage high-speed sampling system or high-precision data meter, to achieve broadband or complex waveform current measurement, or used to calibrate broadband current sources, transformers, sensors, etc. 2. FeaturesOperating frequency: DC ~ 1 MHzAC and DC difference: ≤ 30 ppm @53HzOptimal phase displacement: 5 μradThe nominal output voltage is 1 V (other voltage values can be customized). The typical annual variation is typically 5 ppm and the maximum is 18 ppm. The 1 mA, 10 mA versions mate buffers to reduce output impedance. 3. Applications☆ Set up a broadband current measurement system TH0410 can be used with broadband current source, broadband standard voltmeter (such as TH2000 vector voltage analyzer), etc. to form a broadband current measurement system, which is used to measure broadband current signals, calibrate broadband current sources, broadband ammeters, etc. ☆ Set up broadband power precision measurement system TH0410 can be used with high-frequency V/V conversion standard and TH2000 vector voltage analyzer to form a broadband power/energy precision measurement system for measuring broadband power/ Power signal, calibration of broadband power source, broadband power meter, power analyzer and other equipment. Build a broadband instrument transformer / sensor measurement system For the calibration of the transformer or sensor under test with a nominal current of ≤ 10A, TH0410 can be used directly as the standard device, with a broadband constant current source and a broadband sensor tester ( vector voltage analyzer), etc. to form a broadband transformer/sensor measurement system. Build a broadband transformer/sensor calibration systemFor calibration of transformers or sensors with nominal currents greater than 10 A, TH0410 is used as a secondary signal I/V converter for standard and tested equipment, with broadband constant current source, Broadband sensor testers (vector voltage analyzers), etc. form broadband transformers/sensor measurement systems. ☆ Set up sensor bandwidth calibration system TH0410 can be used with broadband standard voltmeters (such as TH20 0 0 vector voltage analyzer) to form a sensor bandwidth calibration system. 4. Specifications4.1 ResistanceSpecifications Nominal resistance( Z )Initial deviation [1].( ±mH/Z )@ (23±1)°CAnnual stability( ±mH/Z )Temperature coefficient( ±ppm/K )Power factor [2].( ±ppm/rated power ).TH0410-20mA5050182.51TH0410-50mA2050182.51TH0410-100mA1050182.52TH0410-200mA550182.54TH0410-500mA250182.512TH0410-1A150184.025TH0410-2A500 m50184.025TH0410-5A200 m50184.030TH0410-10A100 m50184.060Note [1]: The initial deviation is the maximum offset of the resistance value under DC conditions, usually the manufacturer's factory warranty; Higher accuracy can be customized according to user requirements, such as 20 μΩ/Ω. Note [2]: When measuring DCI with a coaxial shunt, the resistance value changes due to the heat generation of the resistor itself at different input currents, resulting in an error.4.2 Current measurementSpecifications Primary nominal current (A).Secondary nominalVoltage (V).AC/DC difference [3] (±ppm).Maximum operatingCurrent (A).Instantaneous current(A, <5 s)50 Hz1 kHz1 MHzTH0410-20mA20 m120255040m250mTH0410-50mA50 m1202550100m500mTH0410-100mA100 m1202525200m1.5TH0410-200mA200 m1202525500m2TH0410-500mA500 m120252513TH0410-1A112025301.54TH0410-2A2 12030502.56TH0410-5A512030805.520TH0410-10A10120301001130Note [3]: The measured value of AC current should be calculated according to the following formula, and the unit of AC and DC difference is ppm:4.3 Phase displacementSpecifications Phase displacement (±μrad).53 Hz400 Hz1 kHz10 kHz50 kHz100 kHz1 MHzTH0410-20mA5510100400800800TH0410-50mA5510100400800800TH0410-100mA551060300500500TH0410-200mA551060300500500TH0410-500mA551060300500500TH0410-1A551060300500500TH0410-2A10101511050010001000TH0410-5A101525200100020002000TH0410-10A102040300150030003000 5. General SpecificationsPower supply--Temperature performanceWorking temperature: 13°C~33°C; Calibration temperature: 18°C~28°C; Storage temperature: 5 °C ~ 45 °CNote: When stored in harsh temperature environments, it may cause a temporary change in the resistance value and return to the original resistance value within the next 30 days. Humidity performanceOperating humidity: < 50% R· HStorage humidity: (15%~80%) R· H, no condensingaltitude< 3000 mConnection methodInput connection: Type-N type female plug; Output connection: Type-N type female plug. SpecificationsSize( mm ) ( W*D * H )( without terminal blocks )Quality( kg )Dimensional drawingTH0410-2 0 mATH0410-5 0 mATH0410-100mA 65 × 68 × 680.1TH0410-200mATH0410-500mATH0410-1ATH0410-2A82 × 94 × 940.2TH0410-5A TH0410-10A154 × 205 × 20516. Ordering InformationModelNominal currentTH0410-20mA20 mATH0410-50mA50 mATH0410-100mA1,00 mATH0410-200mA200 mATH0410-500mA500 mATH0410-1A1 ATH0410-2A2 ATH0410-5A5 ATH0410-10A10 A
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...