IPDB › China Industry › Instruments & Meters
China, Chinese Commercial Air Conditioning Water Source/Geothermal Heat Pump1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
HeatingRefrigeration Temperature ControlHeat PumpCommercial Air ConditioningWater Source Heat Pump
Jinan Amrta Air Conditioning Co., Ltd.
Preview:
Product Description Commercial Air Conditioning Water Source/Geothermal Heat PumpCharacteristics29 sizes available ranging from 130kW to 2500kW cooling capacity.Acting as multi-function unit such as cooling, heating, sanitary hot water separately or simultaneously.Wide application as hotel, apartment, villa, factory, shopping center, office building, school, etc.Semi- hermetic screw compressor for the whole range. Each compressor is equipped with a crankcase heater and a built-in electronic protection with temperature sensor located directly in the motor winding and on the discharge line.The refrigerant circuit is complete with sight glass, filter drier, high and low pressure gauges, solenoid valve, electronic expansion valve, high and low pressure switch.Shell and tube dry expansion type condenser, factory insulated with flexible close cell material.Shell and tube evaporator, higher efficiency less water consumption, easy maintenance and cleaning, factory insulated with flexible close cell material. The electric panel consists of compressor breaker, compressor contactor, phase sequence relay, control circuit breaker, microprocessor control with function display.LCD display, touch screen control panel as standard.Automatic operation dramatically reducing maintenance cost thanks to reliable microprocessor system. An infinitely variable capacity control system that is capable of exactly matching the demand requirement of the system is to be supplied. This system is to provide precise and stable control of supply water temperature over the complete range of operating conditions.OptionalDesuperheater as optional.Electronic controller with BMS system.Technical DataModelUnitWW130WW170WW200WW240WW260WW280WW310WW360WW380WW420Cooling capacity*Kw130170200240260280310360380420Power supply380-415V/3Ph/50HzCompressorQty/refrigerant circuitNr.1/11/11/11/11/11/11/11/11/11/1Cooling power input*kW26333947515561717583Energy adjustment stepsstep25%-100%Max.current for writingA6987108128154158161165175185Refrigerant chargekg3239465560646885100107EvaporatorWater side pressure dropkPa42454545454646464746Pipe sizemmDN65DN80DN100DN100DN100DN100DN100DN125DN125DN125Water flow rate in cooling*m3/h22293441454853626572CondenserWater side pressure dropkPa42454444454544444442Pipe sizemmDN65DN80DN100DN100DN100DN100DN100DN125DN125DN125Water flow rate in cooling*m3/h27354149545864747886DimensionsLengthmm2685272026602880287031703270317031803180Widthmm1090111511751125112511251230120012851285Heightmm1625155516501645168516851685168518051805Net weightkg1600180019002000210022002250240030003100Noise level**dB(A)68696970707273737373 ModelUnitWW480WW530WW610WW680WW710WW760WW860WW960WW1000WW1120Cooling capacity*kW48053061068071076086096010001120Ton137.1151.4174.3194.3202.9217.1245.7274.3285.7320Power supply380-415V/3Ph/50HzCompressor Qty/refrigerant circuitNr.1/11/11/11/12/22/22/22/22/22/2Cooling power input*kW94104120134140150169189197220Energy adjustment stepsstep25% - 100%12.5% - 100%Max. current for wiringA2582923023352×1652×1752×1752×1852×2462×258Refrigerant chargekg126142160167171199210220242261Evaporator Water side pressure dropkPa46464647474647464646Pipe sizemmDN125DN125DN125DN150DN150DN150DN150DN200DN200DN200Water flow rate in cooling*m3/h8391105117122131148165172193Condenser Water side pressure dropkPa42424442444244424444Pipe sizemmDN125DN125DN125DN1502×DN1252×DN1252×DN1252×DN1252×DN1252×DN150Water flow rate in cooling*m3/h99109126140146156177198206231Dimensions Lengthmm3505350535053520406045054505450546604660Widthmm1280131513751380141514151415141514601460Heightmm1970199019801980197520002000200020902090Net weightkg3500380040004100421044004740560066006800Noise level**dB(A)74747473747474747474 ModelUnitWW 1200WW1250WW1360WW1470WW1720WW1840WW2000WW2350WW2500Cooling capacity*kW120012501360147017201840200023502500Ton342.9357.1388.6420491.4525.7571.4671.4714.3Power supply380-415V/3Ph/50HzCompressor Qty/refrigerant circuitNr.2/22/22/24/44/44/44/44/44/4Cooling power input*kW236246268289339362394463492Energy adjustment stepsstep12.5% - 100%6.25% - 100%Max. current for wiringA2×2922×3022×3154×1754×1854×2464×2584×2584×292Refrigerant chargekg295302327338393430453494537Evaporator Water side pressure dropkPa464646454546464747Pipe sizemmDN200DN200DN2002×DN1502×DN1502×DN2002×DN2002×DN2002×DN200Water flow rate in cooling*m3/h206215234253296316344404430Condenser Water side pressure dropkPa444245525252525252Pipe sizemm2×DN1502×DN1502×DN1502×DN2002×DN2002×DN2002×DN2002×DN2002×DN200Water flow rate in cooling*m3/h247257280303354379412484515Dimensions Lengthmm466046604660460046504690460047804800Widthmm158515851585225022702300245024502450Heightmm221522152240235023802410246024702500Net weightkg700074008000880090009800116001230013000Noise level**dB(A)747475768080818181* Performance values refer to the following conditions:Condenser water inlet/outlet temperature: 30oC/35oC, evaporator water inlet/outlet temperature: 12oC/7oC. ** Noise level measured in free field condition at distance of 1 meter.Project Ordering Process
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...