IPDB › China Industry › Instruments & Meters
China, Chinese 4-20mA/Profibus Smart Temperature Transmitter, Multipoint Temperature Monitoring for Facility Protection1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
TransmitterTemperature Humidity TransmitterMultipoint Temperature Monitoring for Facility ProtectionTemperature TransmitterTemperature Transducer
Hefei WNK Smart Technology Co., Ltd.
Preview:
Product Description WNK6XT Multi-channel Temperature Transmitter (4 channels)Our PROFIBUS-PA field bus WNK6T temperature transmitter is approved by PROFIBUS Nutzerorganisation e.V. For temperature sensor we can provide the thermal resister, thermocouple etc usually used in industry, we can also provide special sensor, including high temperature type,high pressure type,health type,with special material or with coating etc sensor. Customized sensor is also acceptable.Features-WNK6XT Temperature Transmitter1. High precision, digital precision up to :±0.01oC2. Long-term drift<0.1/year3. Install easily, more flexiable4. To reduce the overall cost of installation,maintenance and running.5. 4~20mA/Hart/Profibus PA output all available6 Self-diagnostics function7. LCD display, Menu-guided operation.Optional DP signal multi-channel simultaneousoupt output, it not only increase the safety of on site monitoring, furthermore it save your equipement expense Technical data 1.Input 1.1 Thermal Resistor MeasurandTemperatureMeasuring RangePer connected sensor type (specified sensor range)Sensor type4 types of sensor for option · PT100 · PT1000 · CU50 · CU100Voltage MeasurementTemperature-linearitySensor current≤0.3mA 1.2 Resistive sensor MeasurandOhmic resistanceMeasuring Range4 levels range for option · 0...100 Ohm · 0...260 Ohm · 0...390 Ohm · 0...3900 OhmVoltage MeasurementResistance-linearitySensor current≤0.3mASensor typeLinear resistive sensor, two or three or four wires type 1.3 Thermocouple MeasurandTemperatureMeasuring RangePer connected sensor type (specified sensor range)Sensor typeThermocouple · S type Pt10Rh-Pt(DIN IEC 584) · R type Pt13Rh-Pt(DIN IEC 584) · B Type Pt30Rh-Pt6Rh(DIN IEC 584) · K type NiCr-Ni(DIN IEC 584) · N type NiCrSi-NiSi(BS 4937 Part 2) · E type NiCr-CuNi(DIN IEC 584) · J type Fe-CuNi(DIN IEC 584) · T type Fe-CuNi(DIN 43710)Voltage MeasurementTemperature-linearityCold end compensationModality specification ·No compensation (dual channels) ·Internal access, with built-in or external sensors: PA parameter of manufacturer should be set for external sensor (the default is built-in sensor) ·External specified cold end temperature can be set to a fixed value 1.3 Thermocouple MeasurandTemperatureMeasuring RangePer connected sensor type (specified sensor range)Sensor typeThermocouple · S type Pt10Rh-Pt(DIN IEC 584) · R type Pt13Rh-Pt(DIN IEC 584) · B Type Pt30Rh-Pt6Rh(DIN IEC 584) · K type NiCr-Ni(DIN IEC 584) · N type NiCrSi-NiSi(BS 4937 Part 2) · E type NiCr-CuNi(DIN IEC 584) · J type Fe-CuNi(DIN IEC 584) · T type Fe-CuNi(DIN 43710)Voltage MeasurementTemperature-linearityCold end compensationModality specification ·No compensation (dual channels) ·Internal access, with built-in or external sensors: PA parameter of manufacturer should be set for external sensor (the default is built-in sensor) ·External specified cold end temperature can be set to a fixed value 1.4 Millivolt sensor MeasurandDirect voltageRange ability4 levels range for option · -20...20mV · -50...50mV · -75...75mV · -750...750mVSensor typeLinear mV sensorVoltage MeasurementVoltage-linearInput Resistance≥1MΩSensor current180μA 2. Output Output signal4~20mA/ HART or digital bus (PA/DP/FF) signal.Bus Voltage· 9~32V( without Ex protection) · 9~24VIntrinsically safe type ( details refer our Ex certificate) Effective internal inductance Li<10mH Effective internal capacitor Ci<5nFCommunication ·PA Communication1,2 layer per Profibus-PA,transmission technology by IEC1158-2;Slave function;The seventh layer (the agreement layer) by PROFIBUS-DP,EN50170 standard,with extended PROFIBUS function (all data are non-periodic, measured values and state are periodic) ·DP Communication ·FF Communication H1 bus technique, transmission technique per IEC61158-2 ·Equipment style PROFIBUS-PA style B, industry rule 3.01 ·Equipment address 126( set when shipment)Temperature Unit°C,K, °F, °R for option 3. Measurement accuracy Influence ·Internal cold end compensation error <0.25oC±0.1%/10oC·Temperature drift±0.05%/10oC full-scale range, 0.1% between-10°C to 60°C·Effect of power supply on range<0.005%/V full-scale range ·Long term drift<0.1/yearFor more technical details, please contact with us.Ordering InformationModelProduct descriptionWNK6XTSmart Multi-channel Temperature TransmitterCodeApprovalsAFor non explosion-proof areas U1ATEX II 1/2G EExia II CT62ATEX II 1/2G EExia II CT6,overflow protection WHG 3ATEX II 1/2D4ATEX II 1/3GD EExia II CT65ATEX II 1/3D6ATEX II 2G EEx d II T67ATEX II 3G EEx nA II CT6For other approvals or more information,please contact usCodeChannel numberA2B4C6D8CodeOutput, Display, OperationA4...20mA ,LCD,external button operation, maximum output,B4...20mA HART,LCD,external button operation, maximum outputCPROFIBUS PA,LCD,external button operation, multiple channels output simultaneouslyDPROFIBUS DP,LCD,external button operation, multiple channels output simultaneouslyFFF,LCD operation outside, multiple channels output simultaneouslyCodeInput Measuring rangeOAOhm, 0~100ΩOBOhm, 0~260ΩOCOhm, 0~390ΩODOhm, 0~3900ΩOEOhm, PT 100OFOhm, PT 1000OGOhm, CU 50OHOhm, CU 100DAVoltage, - 20~20 m VDBVoltage, - 50~50 m VDCVoltage, - 75~75 m VDDVoltage, - 750~750 m VRAThermocouple, SRBThermocouple, RRCThermocouple, BRDThermocouple, KREThermocouple, NRFThermocouple, ERGThermocouple, JRHThermocouple, T Code Calibration,unit1Calibration:rated range,°C2Calibration:rated range,°F3Calibration:rated range,°RTypical model#:WNK 6 XTABBOE 1 (4 channels HART smart temperature transmitter with maximum output) Typical model#:WNK 6 XTABDOE 1 (4 channels PROFIBUS DP smart temperature transmitter with 4 channels output simultaneously)Payment Terms1. Port of Loading: Shanghai China 2. Samples Lead Time: 3-7 working days3. Delivery Time: 7-15 working days after payment 4.Payment: T/T, Western Union, Paypal After-sales serviceWe promise to deliver the following after-sales service:1. Warranty: The warranty period is 12 months starting from the shipping date; 2. Customers will enjoy free repair services for failures found within the warranty due to manufacturing quality;3. For on-site services not caused by manufacturing quality, we shall charge a certain service fee at our discretion based on actual charges such as travel expense;4. We provide paid repair services for meter damages not arising from manufacturing quality issues or meter damages not within the scope of warranty. FAQ Q: Are you trading company or manufacturer ?A: We are a manufacturer since the year 2004, committed to producing high accuracy, long-term stability, cost-efficient pressure/level/temperature measuring instruments.Q: What's your quality control system?A: Our factory is cerrified under ISO 9001-2015. All products are completed with temperature compensation and 48 hours aging test before shipment.Q: What is the warranty of your products?A: 12 month from shipment date, for non-man-made damages.Q: Shipping and DeliveryA: Small orders are delivered with DHL, Fedex, TNT, UPS , with delivery time in 4 - 5 business days.Large orders are recommended to ship by seaIf you have another question, pls feel free to contact us as below
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...