IPDB › China Industry › Instruments & Meters
China, Chinese Safety Light Curtains-15SLC0115-P008AD1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
SensorPhotoelectric SensorSafety Light CurtainsSafety Gratings
Shenzhen Tongchuang Mechatronics Co., Ltd.
Preview:
Product Description Performance characteristics SLC-AD safety light grid is designed with the most advanced international functional safety concepts and technologies to provide customers with a safe workplace, with the following advantages: TYPE4 security levelSLC-AD complies with ISO13849-1, Cat.4 category, and reaches PLe safety level; Complies with IEC/EN62061 and IEC/EN61508SIL3 safety levels;Complies with Type4 safety based on EN/IEC61496-1/-2 and GB/T19436-1/-2. No blind zone designSuitable for structurally constrained applications,it's easy to build comprehensive blind zone protection area when applying multiple L or U-shaped combinations. Multiple sets of cascadesThree sets of light curtains cascade combinations can be realized. The cascade combination effectively prevents mutual optical interference between multiple sets of light curtains Optical/line synchronization optional designSLC-AD can realize optical or line synchronization optionally, and different synchronization methods can be selected according to the field situation. Redundant OSSD output with self-diagnosticsDual independent redundant outputs are used,drive safety relays or safety PLC to improve the safety performance of the system Multiple optional setting functionsSLC-AD safety light curtain can be easily configured with functions such as interlock reset, external EDM, bypass and override, and fixed shielding and floating shielding through PC software, and qualified user operators can easily configure functions according to site usage. External relay contact monitoring (EDM) functionThe "External Relay Contact Status" is monitored to prevent the loss of safety protection functions due to external relay adhesion failures. Interlock and reset functionThe light curtains has optional interlock and reset functions, which can be easily implemented for manual reset and automatic reset. Bypass and override functionsIt is convenient to shield light grids for short periods of time under specific conditions without affecting machine operation. Fixed and floating shieldingFixed shielding facilitates special areas with shielding. Floating shielding is convenient for small and large workpieces and can also be used in scenarios where workpieces continue to pass.Technical parametersSystem parametersProjectParameter Safety standardsIEC61496-1,EN61496-1, GB/T19436-1(Type4 ESPE); IEC61496-2, EN61496-2, GB/T19436-2(Type4 AOPD); ISO13849-1 ( PLe,Cat.4);IEC62061, EN62061(SIL3) IEC61508, EN61508 (SIL3)PHFd3.17×10-8MTTFd312 yearsPower protectionPower supply reverse/short circuit ground protectionInput/output protectionAll inputs/outputs are shorted to power or ground protectionOptical axis spacing7.5mm/15mm/30mmResolution14mm/25mm/40mmSynchronization modeOptical/wire synchronization (optional depending on wiring method)System startup time5sResponse timeReference selection tableAperture degree (EAA)±2.5oProtection length0.1~6mProtection degreeIP65Anti-interference>10,000lx ambient illuminationTemperatureWorking temperature -10~55°C (no freezing)HumidityMaximum relative humidity 95% (no condensation)StorageStorage temperature -20-85°C, maximum relative humidity 95%Vibration resistance10-55HZ amplitude 0.7mmImpact resistance10g 16ms 1000 times in the x.y ,z directionEmission parametersProjectParameterSupply voltage24V±15%Supply currentMax 150mAEmit LED wavesInfrared LED (peak wave 940nm)Receive parametersProjectParameterSupply voltage24V±15%Supply currentMax 150mA (excluding OSSD1 and OSSD2 load currents)OSSD1 or OSSD2 Output type2 NPN or 2 PNPOSSD1or OSSD2Max load current500mAOSSD1or OSSD2Output residual voltage>3VOSSD1or OSSD2 Leakage currentMax 0.1mAOSSD1or OSSD2Max capacitive load0.1μFLoad connection resistanceMax 2.5ΩEDM inputLow level 0-3V, high level 10-30VReset inputLow level 0-3V, high level 10-30V ProductProduct application casesFactory showProducts certification Our ExhibitionCompany Cooperative unitsQ: Can i get some samples ?/Do you offer samples available?A: Yes, we can provide sample, but the cost of the sample is paid by the customer, if you feel satisfied and have the next mass production order, we can deduct the cost of the sample.Q: How is the warranty?A:our warranty time is 18 months. If the product has quality problem within 18 months, please return it to us, we will repair it; if we can't repair it successfully, we will give you a new one; but the man-made damage, improper operation and force majeure will be excepted. And you will pay the shipping cost of returning to us, we will pay the shipping cost to you.Q:How about the quality of the products?A:we have the certification of CE,CCC,CQC,EU,TUV,UL, and products Safety Level archived Ple,SIL,Type 4,Cat.4 etc. Q: What is the quality guarantee? A: We are an ISO 9001-2015 ,ISO 14001 -2015 certified manufacturer, we have strict quality control system. Besides calibration, each set product we also do aging test before shipment, so the quality is guaranteed.Q: Do you have any products in stock?A: Depend on the order quantity.Q: Can I be your distributor?A: Yes, we are looking for distributors in oversea market.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...