IPDB › China Industry › Instruments & Meters
China, Chinese Portable Gas Chromatograph Price Chromatography1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Analysis InstrumentChromatographySpectroscopy InstrumentPortable Gas Chromatograph PriceGas Chromatograph
Chongqing Drawell Instrument Co., Ltd.
Preview:
Product Description Product DescriptionGas ChromatographyDW-GC1290 Product Description DescriptionEPC(electronic pneumatic control) 7 inch touch screen displaySample Introduction Systemsample injector and evaporation chamberColumn OvenTemperature rangeAmbient temperature +7oC ~ 420oC (in 1oC increment)Temperature accuracy ± 0.02oCCooling time350oC~100oC≤3min, 400oC~50oC in 8-10 min at 25oC ambientProgrammed temperature setting0.1oC~80oC/min (in 1oC increment)Program ramps20 ramps in total (99 ramps available with control workstation)Size (L*W*H)284*280*241mm(inside)340*345*281mm(outside)Flame Ionization Detector (FID)Detection limit≤8×10-12g/s (n-hexadecane)Drift≤1.5×10-13A/hNoise≤3×10-14ALinearity range≥106Flame Photometric Detector(FPD)Detection limit≤8×10-13g/s(P) ; ≤8×10-11g/s(S)Drift≤2×10-11A/30minBaseline noise≤5×10-12ANitrogen-Phosphorus Detector(NPD)Detection limit≤5×10-12g/s(N) (Azobenzene) ≤5×10-13g/s(P) (Malathion)Features: *Control system: designed for monitoring and controlling the instrument via the computer.*Column Compartment/oven with superior thermal performance, multistage (20 ramps) programmed temperature control function. (supported by "control system")*Advanced built-in data acquisition system , supporting real time instrument status monitoring, detection signal acquisition and PC control*Column oven supports quick heat-up and rapid cool-down with automated back-door opening.*Flexible sample introduction system: 2 sample injectors could be installed and operated simultaneously with independent temperature control.*High sensibility and stability detector.*2 independent and analog signals output.*M6 software, compatible with GLP-21 CFR Part11 requirements and regulations. (electronic records and signatures)Electronic pneumatics control systemFlow rate: 200ml/min (N2), 1000ml/min (He)Flow rate accuracy: ±5%Flow rate repeatability: ±0.35%Split ratio: 0-5000(He), 0-1000(N2)Inlet temperature: 0-420oC Gas chromatography and accessories:Carrier Gas System + Sample Introduction System + Separation System + Temperature Control System + DetectorCarrier Gas System: air source/ purification and desiccation device/ flow rate control deviceSample Introduction System: sample injectorSeparation System: chromatographic column(packed column and capillary column)Temperature Control System (Column Oven): constant temperature and programmed temperatureDetector: FID/ FPD/ NPD Company ProfileFAQ
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...