IPDB › China Industry › Instruments & Meters
China, Chinese R410A Swimming Pool Heat Pump with Titanium Heat Exchanger1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
HeatingRefrigeration Temperature ControlHeat PumpSwimming Pool Heat PumpHeat Pump
Shenzhen Eurostars Technology Co., Ltd.
Preview:
Product Description 1.Application of Air Source Swimming Pool Heat PumpEurosatrs House Spa and Commercial Swimming Pool Heat pump are specially developed for commercial pool or spa water temperature control. With intelligent control system are let the units high efficiency and stable working performance. The COP of this type heat pump can reach 5~ 5.4 at some working condition, which saves you at least 80% energy;Suitable for large pools in hotel, public parks, schools, sport center, gyms, house spa, etc.2.Eurostars Air Source Swimming Pool Heat Pump Features:Eurosatrs Swimming Pool Air Source Heat Pumps with following features:1. PVC Titanium heat exchanger with full resistanc.2. Compact structure, easy demountable for access.3. High efficiency compressor, saving energy.4. Flow switch for water flow protection.5. Intelligent controller and adjustment by quick mind microprocessor.6. Intelligent LCD display wired controller.7. Air side heat exchanger (fins-coil )with hydrophilic coating.8. Automatic defrosting function included.9. Optional: stainless steel cabinet; 50Hz/60Hz power3. Air Source Swimming Pool Heat Pump Technical DataAir Source Heat Pump Unit(Swimming Pool Heat Pump)ModelESSA-05HPESSA-05HPESSA-05HPESSA-05HP2.5ES3.5ES4.5ES3.5ESHeating Air DB/WB: 24oC/16oCWater tempt: 28oCKW10.215.118.515.1x 1000 Kcal/h8.813.015.913.0RT2.94.35.34.3Input power (KW)1.942.953.602.94COP5.265.125.145.14Cooling Air DB/WB: 35oC/24oCWater tempt: 28oCKW6.69.812.09.8x 1000 Kcal/h5.78.410.38.4RT1.92.83.42.8Input power (KW)2.113.213.923.20EER3.143.063.073.07Compressor TypeHermetic ScrollThrottle TypeExpansion ValveRefrigerant R410APower Supply220~240V/50Hz380~420V/50Hz ModelESSA-05HPESSA-10HPESSA-10HPESSA-12.5HP4.5ES6ES2*4.5ES2*6ESHeating Air DB/WB: 24oC/16oCWater tempt: 28oCKW20.226.140.452.2x 1000 Kcal/h17.422.434.744.9RT5.77.411.514.8Input power (KW)3.965.117.9210.22COP5.105.115.105.11Cooling Air DB/WB: 35oC/24oCWater tempt: 28oCKW13.117.026.333.9x 1000 Kcal/h11.314.622.629.2RT3.74.87.59.7Input power (KW)4.315.568.6211.12EER3.053.053.053.05Compressor TypeHermetic ScrollThrottle TypeExpansion ValveRefrigerant R410APower Supply380~420V/50Hz ModelESSA-15HPESSA-20HPESSA-25HP 2*7ES4*4.5ES4*6ES Heating Air DB/WB: 24oC/16oCWater tempt: 28oCKW60.580.8104.4 x 1000 Kcal/h52.069.589.8 RT17.223.029.7 Input power (KW)11.9415.8420.44 COP5.075.105.11 Cooling Air DB/WB: 35oC/24oCWater tempt: 28oCKW39.352.567.9 x 1000 Kcal/h33.845.258.4 RT11.214.919.3 Input power (KW)12.9917.2322.24 EER3.033.053.05 Compressor TypeHermetic ScrollThrottle TypeExpansion ValveRefrigerant R410APower Supply380~420V/50Hz4.Air Source Swimming Pool Heat Pump Main Components Introduction1) Base frame and external panels are made of galvanized sheet.2) High efficiency compressor with R410A Refrigerant.3) Touch design LCD control panel, and the control signals are easier to be transferred to the control system;4) Openable cabinet door design for faster and simpler checking and maintenance5) Well heat insulation inside the unit to increase the COP. 6) Exterior rotor fan ensures lower noise and vibration7) Lovely outlook and sharp edges reduction cabinet design8) High quality copper tube coils constructed of thread technology9) Automatic defrosting function included.10) Clock & Timing on/off function.11) General testing and operational test carried out for every unit before package in the factory.12) With full protection functions including water flow, high/low pressure, phase order, over-current etc.13) Big evaporator to extract more heat from the air.14) Metal Galvanized powder coated frame15) For low temperature area: -25oC(optional);5. EUROSTARS Air Source Scroll Heat Pump Range:(1) Water source heat pump(2) Geothermal source heat pump(3) Air source heat pump, including swimming pool heat pump(4) EVI air source heat pump (5) Split heat pump(6) DC Inverter heat pump6.About USWe, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.Webiste 1: http://eurostarschiller.en.made-in-china.comWebsite 2: http://eurostarschiller.en.made-in-china.com Instagram: https://eurostarschiller.en.made-in-china.comFacebook: https://eurostarschiller.en.made-in-china.comYoutube https://eurostarschiller.en.made-in-china.com 7.FAQQ:How does the Swimming Pool Heat Pump Work?Heat pumps use a small amount of driven electricity to absorb heat and transport it from one place to another. Indeed, they couldn't generate heat. As swimming pool's water circulated by the pool pump, the water get from the pool passes through a filter and pool heater. The pool heater has a fan that brings in the outside air and guides it over the evaporator coil. Liquid refrigerant within the evaporator coil absorbs the heat from the outside and then evaporate gas. The evaporated gas in the coil then flows through the compressor. The compressor pump to increase the heat, generate a very hot gas that then flows through the condenser. The condenser moves the heat from the hot gas to heat the cooler pool water circulating through the heater. The heated water then flow into the pool. The hot gas, as cross flows through the condenser coil, back to liquid form and return the evaporator, where the whole process begins again. Higher efficiency heat pump pool heaters usually use scroll compressors versus the rotary compressors of standard composition. Heat pump pool heaters work efficiently as long as the outside temperature remains above the 7oC-10oC range. The cooler the outside air they bring in, the more energy they exhaust. However, since most people adopt outdoor swimming pools during summer or mild weather, this usually isn't an issue.Q:Compared with other products, what's the advantage of Eurostars heat pumps?a. High heating efficiencyb. Low cost: compared with the fuel or gas furnace, the heat pump can save 70% of the energy.c. Environmental protection: there is no emission resulting from burning. The refrigerant for the heat pump is environmentally-friendly refrigerant such as R410A, R407C, R134A which will not destroy the ozonosphere.d. Safety: the operation of the heat pump is safe and automatic.e. Provide OEM/ODM service8.Customer visit us9.Air source heat pump delivery or container loading10.Installation instruction or installation photo, project photosA,Place selection of installation Heat pump 1). Heat pump should be installed in a large space, and have good air flow condition. 2). Air inlet and outlet must be a clear road, the distance from barrier to inlet and outlet must be longer than 2m. 3). Set drain ditch or drain outlet, so that can drain water easily. 4). The installation base or bracket must be firm, make sure heat pump work balancely. 5). Make sure heat pump is vertical, can't be slanted. 6). Don't install heat pump at the place in where there is plenty of pollutional and corrosive gas or sand or fallen leaves. 7). The installation place can't be near inflammable, flammable thing or fire. 8). Installation:---The installation base can be concrete construction, or steel bracket, and must use anti-vibration rubber pad, And the surface should be smooth.---The design of installation base can be according to heat pump weight.---The heat pump bottom should be fixed by bolt.B,Pipe connectionThe drain pipe and overflow pipe should be installed near drain ditch or drain outlet, easy to drain, and install drain water valve on drain pipe before magnetic valve there should be service valve on water pipe. If use plastic pipe (such as PPR pipe or ABS pipe), users should consider pipe expand and contract problem between heat pump and water tank. Water supply valve and cut-off valve maybe need insulation (according to local weather condition),avoid frost crack.C,Water pipe system installationWater pipe should be straight, and the arrange should be reasonable, reduce bend as little as possible. Reduce the water pipe resistance.There can't be leaking at any place of pipe.After all equipments and pipes installation finished, users should test water pressure, and drive air out, drain dirty out, make sure water cycle system is clean. After confirm there is not any problem, then insulate all hot water pipes.D,Power supply wiring 220V heat pump use single phase power supply, 380V heat pump use three phase power supply, wire line is 3phase 4lines, A B C connects live line, N connects null line, E connect earth. Be sure not to connect N line to live line of power supply. 1).When repairing, please turn power supply at "off" side. 2).Power supply connecting process:make sure a equipment power supply is cut off before its installation is finished. Install power supply switch at suitable place, Use rubber hole for wiring line in electric box.Power supply demand:220V rated voltage±10%380V rated voltage±10%frequency:50Hz rated frequency±2% 3).if power supply fluctuation is out of demand, please don't start your heat pump.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...