IPDB › China Industry › Industrial Equipment & Components › Power & Generating Sets
China, Chinese Factory Price Diesel Genset Cummins/Perkins/Mtu/Mitsubishi/Sme 2000kw 2250kVA 2500kVA 2750kVA 3000kVA 3750kVA 3000kw Standby Electric Power Generator1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Power Generating SetsElectric GeneratorPower Generator
MECCA POWER CO., LTD.
Preview:
Product Description Mecca Power, as part of a Global Power Supplier initiative, provides a professional solution for the design, application and after-sales support of generators.Strongly focused on innovation and the inherent flexibility of product design, Mecca Power has been successful in global markets with a broad and diverse range of genset power products that can operate autonomously or independently. parallel, on-site or remotely controlled.With more than 10 years of experience in manufacturing and exporting energy products, the Mecca team will advise you on product choices. Product DescriptionSpecificationPowered by MTU 50HZ 220-440 V 500-3300KVA ModelLTPPRPEngineFuel Cons.Cyl.Disp.Gov.KVA / KW KVA/KW ModelOriginL/H(100%)LMC500M500400 450360 10V1600G10FDE101.310V17.5ADECMC550M550440 500400 10V1600G20FDE110.910V17.5ADECMC660M660528 600480 12V1600G10FDE131.712V21ADECMC725M725580 660528 12V1600G20FDE144.912V21ADECMC880M880704 800640 12V2000G65CN184.012V23.9ADECMC1000M1000800 900720 16V2000G25CN210.016V31.8ADECMC1100M1100880 1000800 16V2000G65CN230.816V31.8ADECMC1250M12501000 1125900 18V2000G65CN264.516V31.8ADECMC1375M13751100 12501000 18V2000G26FCN261.118V35.8ADECMC1500M15001200 13501080 12V4000G23RDE307.612V57.2ADECMC1650M16501320 15001200 12V4000G23DE351.512V57.2ADECMC1800M18001440 16251300 12V4000G23DE351.512V57.2ADECMC2000M20001600 18121450 12V4000G63DE398.212V57.2ADECMC2250M22501800 20501640 16V4000G23DE452.116V76.3ADECMC2500M25002000 22501800 16V4000G63DE491.616V76.3ADECMC2750M27502200 25002000 20V4000G23DE561.820V95.4ADECMC3000M30002400 27502200 20V4000G63DE611.620V95.4ADECMC3300M33002640 30002400 20V4000G63LDE651.220V95.4ADECPowered by MTU 60HZ 220-480V 625-4000KVA ModelLTPPRPEngineFuel Cons.Cyl.Disp.Gov.DimentionWeightKVA / KW KVA/KW ModelOriginL/H(100%)LL*W*H (MM)KGSMC625M62550056345010V1600G20SDE114.110V17.5ADEC3225*1485*20703870MC688M68855062550012V1600G10SDE135.512V21ADEC3387*1531*21404890MC750M75060068855012V1600G20SDE145.212V21ADEC3387*1531*21403784MC875M87570080064012V2000G45CN179.612V23.9ADEC4100*1810*21306100MC1000M100080090072012V2000G85CN196.912V23.9ADEC4100*1810*21306900MC1125M1125900102582016V2000G45CN219.216V31.8ADEC4495*2122*22957000MC1250M12501000113891016V2000G85CN240.816V31.8ADEC4495*2122*22957150MC1500M150012001375110018V2000G85CN281.118V35.8ADEC4840*1825*21658200MC2000M200016001819145512V4000G43DE348.212V57.2ADEC6150*2150*250012500MC2200M220017602000160012V4000G83DE405.712V57.2ADEC6350*2150*250013000MC2500M250020002250180016V4000G43DE469.816V76.3ADEC7085*2250*250014500MC2875M287523002625210016V4000G83DE535.516V76.3ADEC7085*2250*250015000MC3125M312525002875230020V4000G43DE598.820V95.4ADEC7160*2555*293020500MC3438M343827503125250020V4000G83DE651.720V95.4ADEC7160*2555*293021000MC4000M400032003637.5291020V4000G83LDE693.920V95.4ADEC7160*2555*293021000View more products click here...Genset WorkshopFAQ1.Q: What is your MOQ of this item?A:1 Set2.Q: What are your payment terms?A:30% TT as deposit,70% TT before Shipment or 100% LC at sight3.Q:What's the warranty time of diesel generators?A:Global Warranty: 12months after delivery or 1000 running hours, whichever come first.4.Q:Can you accept the customized products?A:Yes, of course.We accept your specific order if you can provide us your special requirements or special samples5.Q:What's the delivery time ?A:20 to 35 days after receiving your payment in advance.6.Q:Do you offer OEM service?A: Yes7.Q:What is the power range do you have?A:Mecca Power assemble genset from 2 to 4000kva8.Q:What's your special compare to other manufacturer?A:We can delivery genset 1000units/month as engine and alternator OEM and Strategic partners. Especially for big quantity and big power projects, we support not only by solutions and tender documents, but also by fast delivery time and good price.-----------------------------------------------------------------------------------------------MAITAINENCE---------------------------------------------------------------------------------------------General Troubleshooting This section lists the generating set for some common fault, the reasons for the failure and determines the method of fault. General operators can determine their own fault and note, maintenance it according to the brochure. But please contact the repairing agents when meeting a special note or not listed failure of operation. Please remember the following suggestions before repairing: - Make sure that study the failure carefully before any operation. - Repair with the easiest way and most commonly used method. - Find the exact causes of failure and completely solve the fault. 1. Generator Sets Description of this section is for reference only. If the following failure occurs please contact the repairing agents. (Some models of control panel installed only parts of the following warning indicator light)IconIndicator LightReasonFault AnalysisLow oil pressurealarmLow oil pressurealarmWhen oil pressure does notreduce normally, the light is on.-General because of a lack of oil or lubricationsystem failure caused by (refueling or replacingthe oil filter)-When occurs this fault should automaticallyshutdown generator sets immediately.High watertemperaturealarmHigh watertemperaturealarmWhen the water temperaturehas risen to a level higher thanor equal to the sensor setting,the light is on.-General because of a lack of water or oilshortage, or overload.-When occurs this fault should automaticallyshutdown generator sets immediately.Low fuel levelalarmLow fuel levelalarmWhen a fuel level has beendetected by the sensor fitted tothe daily tank, the light is on.-General because of a lack of water or oilshortage, or overload.-When occurs this fault should automaticallyshutdown generator sets immediately.Battery chargerfault alarmBattery chargerfault alarmIf the charging system has fault,when engine running, the light isoff.-Battery charging system fault caused.-The light is on at the initial start, when thecharger reaches a certain speed, the light is off.-This failure will not lead to automatic shutdowngenerating units.Crank failurealarmCrank failurealarmWhen the generator set failedthree times (or six times) in arow starting, the light is on.-Oil supply system or re-start the system failurecaused.Overload orbreaker trippingalarmOverload orbreaker trippingalarmWhen overloading or Shortcircuit, the light is on. Trippingcircuit breakers cause generatorset load out.-In this fault, it need to load or unload some partsto eliminate short-circuit, and then re-close thecircuit breaker.Introduction of Maintenance grade(Interval) for the generator set A Level Maintenance Interval (Daily Maintenance)1. Check Daily Report of Genset .2. Check fuel level and coolant level. 3. Check alternator for cracks or other damage, and the condition of the belts must be checked, flab or other damage.4. Check the Air filter. The air filter should be replaced when necessary .5. Release fuel tank and fuel filter's water and sediment.6. Check the water cooling filter.7. Check starting battery and electrolyte, add electrolyte when necessary. 8. Check the starter, check noisy defect.9. Use air syringe cleaner to clean the water tank, coolant system and cooled fin net.B Level Maintenance Interval (Less than 400 hours)1. Repeatedly check A Level Daily Maintenance steps.2. After operating 100 to 250 hours, replace the fuel filter. All the fuel filters should not be cleaned, it should be replaced. 100 to 250 hours is just flexible time, actually it must be according to the practice and real fact. 3. After operating 200 to 250 hours, replace the oil & oil filter. All the lube oil must fit up to the CF Grade of American Petroleum Institute.4. After operating 300 to 400 hours, replace the air filter. The air filter can be cleaned with air syringe, or it can be replaced. The replacement must be according to the environment and real fact.5. Replace the cooling system and add coolant concentration.6. Clean the crankshaft and inlet, outlet air- filter net. C Level Maintenance Interval (2000-3000 hours), Please do as follows:1. Repeatedly check A and B Level Daily Maintenance steps.2. Remove the tap of valve, clean and wash oil dirt and sludge.3. Fasten snails from each part (including running parts and fixed parts)4. Clean and wash the crankcase, oil sludge, steel scraps and sediment with engine.5. Check wearing of the engine turbo, clean and wash accumulation of carbon, adjust it when necessary.6. Check and adjust valve clearance.7. Check PT pump, quality of injection, adjust injection process, adjust it when necessary.8. Check and adjust the tension of fan belt and water pump belt, adjust and replace it when necessary; clean and wash water tank radiator fins, then check the using capability of thermostat.Current Repair (D Level Maintenance)(3000-4000 hours)1. Check valve, valve seat and other wearing, repair or change it when necessary.2. Check P pump, quality of injection, repair and adjust it when necessary.3. Check and adjust connecting rod and fastening twisting torque.4. Check and adjust valve clearance.5. Check the trip of injector.6. Check and adjust tension of fan and generating belt.7. Clean and wash accumulation of carbon in inlet pipes.8. Clean and wash the core of air cooler.9. Clean and wash the whole oil lubrication system.10. Clean and wash room of rocker arm, oil sludge in the sump and Metal scrap-iron.Medium Repair (6000-8000 hours)1. Including the items of minor repair.2. Disassemble generator(except crankshaft)3. Check the easy worn spare parts in pitman shaft system, gas distribution system, lubrication system, cooling system of cylinder, Piston, Intake and exhaust valve, replace them when necessary.4. Check fuel supplying system, adjust oil pump and injector.5. Repair and test the alternator, clean oil-sediment and lubricate the bearing of alternator.Overhaul (9000-15000hours)1. Including the items of intermediate repair.2. Disassemble all the parts in the generator.3. Replace cylinder, piston, piston loop, big and small bearing bushes, trusting pad of crankshaft, intake and exhaust valve, a whole set of tools for generator repair 4. Adjust oil pump, injector and replace pump core, injector5. Replace a whole set of repair tools for turbo charger and a repair set for water pump.6. Adjust the parts of connecting rod, crankshaft and generator body,repair or replace them when necessary
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...