IPDB › China Industry › Instruments & Meters › Test Instrument
China, Chinese Double Layer High Low Temperature Battery Testing Chamber Manufacturer1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Test InstrumentLithium Battery Temperature Test ChamberHigh Low-Temperature Test Chamber
Dongguan Lituo Testing Instrument Co., Ltd.
Preview:
Product Description It is suitable for electronics, instruments, power batteries, home appliances and other products, parts and materials at high and low temperatures.Adaptability test (reliability test) for storage, transportation and use in alternating, high and low temperature environments.Technical parameters1. Inner box size (W*H*D) : Double layer, each layer W600*D600*H850 (mm)2. Outer box size (W*H*D) : W950*D1900*H2150(mm)3. Temperature range: -40oC ~ +100oC4. Temperature fluctuation: ≤±0.3oC(constant state space-time load5. Temperature uniformity: ≤2.0oC(constant state space-time load6. Temperature deviation: ≤±1.0oC(constant state space-time load7. Rising and cooling rate:Cooling rate: +25oC ~ -40oC≤60min, average cooling rate: (0.7 ~ 1.0) oC/min(the whole average no-load).Heating rate: +25oC ~ +100oC≤40min, average heating rate: 0.5 ~ 3.0oC/min(the whole average no-load8. Common temperature conditions: 60 oC, 45oC, 25oC, 0oC, -10oC, -20oC, -40oC; It is about 3 months longPhase low temperature test condition (-40oC)9. Equipment layout:Circulating water inlet and outlet, spray water inlet and outlet are located on the left, pressure relief port is located on the right;Circulation water inlet and outlet, spray water inlet and outlet are located on the right, pressure relief port is located on the left;Note: From the position of the main door of the equipment; The device configuration ratio in the two layouts depends on the actual purchase requirements.10. Equipment volume: 306L (600×850×600 mm) per layer, a total of 2 layers11. Operation mode: Double-layer independent temperature control, can be set to run or program run.12.Equipment weight: ≤550kg13.Voltage: AC 380V±10%, 50 Hz, three-phase four-wire + ground wire14.Ambient temperature: 0 ~ 40oC15.Ambient humidity: < 85%R.H (25oC)16.Atmospheric pressure: air pressure 86 ~ 106Kpa17.Equipment power: 9kw18.Power distribution circuit breaker specifications: 63A/3P+N19.Equipment wire specifications: 3*6+2*4 (three-phase five-wire system20.Device cable inlet: One cable inlet at the top of the device21.System noise: ≤68dB (500mm from the surface of the equipment and operating bit, respectively)22.Cooling method: water-cooled (customers provide frozen water23.Inlet flow rate: ≤2m3/H24.Water inlet temperature: 5-32oC25.Inlet pressure: 0.2MPa26.Environment heat dissipation: ≤0.3KW27.Equipment fault protection: overheat protection circuit breaker, humidification system overheat protection, compressor overload protection, control system overload protectionProtection, overload indicator light, phase sequence protection, water shortage protection, high pressure and low pressure protection, over temperature protection, water supply delay protection, fan overcurrent protection.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...