IPDB › China Industry › Instruments & Meters › Meter for Electricity
China, Chinese Fluke 725ex Intrinsically Safe Multifunction Process Calibrator1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Meter for ElectricityFluke725ex 726
Shenzhen HOBOY Instruments Co., Ltd.
Preview:
Product Description Source and measure most process parameters such as mA, volts, temperature (RTDs and thermocouples), frequency, ohms, and pressure using optional pressure modules (sold separately) with this process calibrator. It is intrinsically safe for use in explosion endangered areas. Additionally, it features auto-stepping and auto-ramping. Other useful features:Pressure switch test function to capture set, reset, and deadband valuesSmall, streamlined shape, and rugged, reliable design that stands up to field useSimple, push-button user interface for easy operationProvides two-channel simultaneous source and measure capability to calibrate transmittersPowers transmitters during test using loop supplyStores frequently-used test setups for later useMeasures pressure to 3,000 psi/200 bar using any of the eight intrinsically safe Fluke 700PEx Pressure Modules to calibrate pressure transmitters and I/P devicesProduct Parameters Measurement AccuracyVoltage DC30.000 V: 0.02% + 2 counts (upper display)10.000 V: 0.02% + 2 counts (lower display)90.00 mV: 0.02% + 2 counts-10.00 to 75.00 mV: 0.025% + 1 count (via TC connector)Current DC24.000 mA: 0.02% + 2 countsResistance0.0 to 400.0 Ω: 0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire)401 to 1500 Ω: 0.5 Ω (4-wire), 1 Ω (2- and 3-wire)1500 to 3200 Ω: 1 Ω (4-wire), 1.5 Ω (2- and 3-wire)Frequency2.0 to 1000.0 CPM: 0.05% + 1 count1.0 to 1100.0 Hz: 0.05% + 1 count1.00 to 10.00 kHz: 0.05% + 1 countSensitivity: 1 V peak-to-peak-minimumPressureAccuracy from 0.025% of range using any of 8 intrinsic safe pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure.Source AccuracyVoltage DC100.00 mV: 0.02% + 2 counts10.000 V: 0.02% + 2 counts-10.00 to 75.00 mV: 0.025% + 1 count (via TC connector)Current DC24.000 mA (source): 0.02% + 2 counts24.000 mA (simulate): 0.02% + 2 countsResistance15.0 to 400.0 Ω: 0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA)401 to 1500 Ω: 0.5 Ω (excitation current 0.05 to 0.8 mA)1500 to 3200 Ω: 1 Ω (excitation current 0.05 to 0.4 mA)Frequency2.0 to 1000.0 CPM: 0.05%1.0 to 1100.0 Hz: 0.05%1.00 to 10.00 kHz: 0.25%Waveform: 5 V p-p squarewave, -0.1 V offsetRTDs and ThermocouplesMeasure AccuracyNI-120: 32.36°F (0.2°C)PT-100 (385): 32.6°F (0.33°C)PT-100 (393): 32.54°F (0.3°C)PT-100 (JIS): 32.54°F (0.3°C)PT-200 (385): 32.36°F (0.2°C)PT-500 (385): 32.54°F (0.3°C)PT-1000 (385): 32.36°F (0.2°C)Resolution: 0.1°CJ: 33.26°F (0.7°C)K: 33.44°F (0.8°C)T: 33.44°F (0.8°C)E: 33.26°F (0.7°C)R: 35.24°F (1.8°C)S: 34.7°F (1.5°C)B: 34.52°F (1.4°C)L: 33.26°F (0.7°C)U: 33.35°F (0.75°C)N: 33.62°F (0.9°C)Resolution: J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°FXK: 33.08°F (0.6°C)BP: 34.16°F (1.2°C)Source AccuracyNI-120: 32.36°F (0.2°C)PT-100 (385): 32.6°F (0.33°C)PT-100 (393): 32.54°F (0.3°C)PT-100 (JIS): 32.54°F (0.3°C)PT-200 (385): 32.36°F (0.2°C)PT-500 (385): 32.54°F (0.3°C)PT-1000 (385): 32.36°F (0.2°C)Resolution: 0.1°CAccuracy stated for 4-wire measurement.J: 33.26°F (0.7°C)K: 33.44°F (0.8°C)T: 33.44°F (0.8°C)E: 33.26°F (0.7°C)R: 34.52°F (1.4°C)S: 34.7°F (1.5°C)B: 34.52°F (1.4°C)L: 33.26°F (0.7°C)U: 33.35°F (0.75°C)N: 33.62°F (0.9°C)Resolution: J, K, T, E, L, N, U: 0.1°C, B, R, S: 1°CXK: 33.08°F (0.6°C)BP: 34.16°F (1.2°C)Functions SpecificationsRamp FunctionsSource functions: Voltage, current, resistance, frequency, temperatureRamps: Slow ramp, Fast ramp, 25% step-rampLoop Power FunctionVoltage: 12 VAccuracy: 10%Maximum current: 22 mA, short circuit protectedStep FunctionsSource functions: Voltage, current, resistance, frequency, temperatureSteps: 25% of range, 100% of rangeMechanical and General SpecificationsBatteries4 x AA alkaline batteriesBattery ReplacementSeparate battery compartment, accessible without breaking calibration sealSide Port ConnectionsPressure module connectorDimensions5.188 x 9.291 x 2.402" (130 x 236 x 61 mm)Weight1.874 lbs (0.85 kg) Fluke 725ExIntrinsically safe multifunction process calibratorMeets I.S. Class I, Division 1 Groups B-D, 171°C compliance standardsMeasures volts DC, mA, RTDs, thermocouples, frequency, and ohmsSources or simulates volts DC, mA, RTDs, thermocouples, frequency and ohmsThe Fluke 725Ex is an intrinsically safe multifunction process calibrator for use in explosion-endangered areas. It is powerful, yet easy to use. Combine the 725EX with any of the eight Fluke 750PEx Pressure Modules (sold separately), and you'll be able to calibrate almost any process instrument likely to need service in an area where explosive gasses may be present.The 725EX sources and measures almost all process parameters including mA, volts, temperature (RTDs and thermocouples), frequency, ohms, and pressure, using optional pressure modules. Its split display lets you view input and output values simultaneously to calibrate transmitters. For valve and I/P tests, you can source mA while measuring pressure. The 725Ex has auto-stepping and auto-ramping for remote testing, plus 25% stepping for fast linearity tests.From the moment you pick it up, the Fluke 725Ex is ready to perform. Its simple controls, without menus, make operation easy. Its memory functions make set up fast. And its rugged design lets it work as hard as you do. Packaging & Shipping
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...