IPDB › China Industry › Instruments & Meters › Other Instruments & Meters
China, Chinese GF1000 Multi-Positions Single Phase Kwh Meter Test Bench1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Other Instruments MetersKwh Meter Test BenchSingle Phase Kwh Meter Test Bench
Beijing GFUVE Electronics Co., Ltd.
Preview:
Product Description Product DescriptionThe GF1000 series multi-positions single phase kWh meter test bench can measure mechanical meters, electronic mechanical meters and electricity meter error by the way of automatic, semi-automatic or manual operation. It composes of single phase programmable power source, high precision single phase reference energy meter, meter suspension test rack, Multi-channel server and precision clock source etc. GF1000 meter test bench is applied in the measurement centre of grid company energy measurement department of power supply company and energy management utility, industrial enterprise and meter manufacturers. Our AdvantagesFUNCTIONSPre-warming;Meter constant test;Starting current test;Creep test (No-load test);Dips and Interruptions;Dial test (Register test);Equipped with RS232 communication port;Testing single-phase meters under tampered conditions;Calibration of lower accuracy reference standard meter;Able to print out all kinds of test reports with the standard forms;Calibrate all kinds of electronic and inductive single phase kWh meter;Influence quantity test (voltage, frequency, harmonic distortion, etc.);Automatic measurement like shunting, basic errors, standard deviation etc;Accuracy test in all four quadrants (active, reactive and apparent energy);Test voltage, current, active/reactive/apparent power, phase, power factor, frequency, and etc;Able to display waveform of voltage and current able to set 2nd-51st harmonic of voltage and current, measure the waveform distortion and harmonic content, and display harmonic chart; FEATURESWith auto PC control software;With barcode scanning function optional;Meter positions can be chosen from 3 - 48;Self-check and perfect protection function;High resolution of voltage, current and power;Large LCD display and simple interface for operation;Full automatic, semi automatic and manual operation available;Aluminum alloy material,light and strong and corrosion resistant;Wide current measuring range which can be automatically switched;High stability of power source which is up to 0.01%/100s and low distortion which is no more than 0.3%;High accuracy, 6-digit display the energy relative errors are no more than 0.05%(0. 1%)within the measuring range;Equipped with sing phase mulfunction reference meter and progam-conrolled single phase power source which can be separately used and are convenient for testing;Product ParametersPARAMETERSElectrical parametersAccuracy0.02%, 0.05%, 0.1%Power SupplyAC 180-265V, or 3×220/380V±15%, frequency 50/60Hz.AC Voltage OutputRange57.7V, 100V, 220V, 380V (max 480V)Adjustment range(0-120)%RG(1)Adjustment fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.Stability0.01%/120sDistortion0.3% (Non-capacitive load)Output load1500VAMeasuring accuracy0.02%RG or 0.05% RGAC Current OutputRange(I1,I2,I3)0.1A, 0.25A, 0.5A, 1A, 2.5A, 5A, 10A, 25A, 50A, 100A, 120AAdjustment range(0-120)%RGAdjustment fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.Stability<0.01%/120sDistortion≤0.3% (Non-capacitive load)Output load1500VAAccuracy0.02%RG or 0.05% RGPower OutputActive power output stability<0.01%RG/120sReactive power output stability<0.02%RG/120sActive power measuring accuracy0.02%RG or 0.05% RGReactive power measuring accuracy0.1%RGPhase OutputOutput adjustment range0°-359.999°Output adjustment fineness10, 1, 0.1, 0.01 as optional.Resolution0.01°Accuracy0.02° or 0.05°Power FactorAdjustment range-1 ~ 0 ~ 1Resolution0.0001Measurement accuracy0.0005Frequency OutputAdjustment range40Hz-70HzOutput adjustment fineness5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.Resolution0.001HzAccuracy0.002HzVoltage /Current/Harmonic SettingHarmonic number2-51timesHarmonic content0-40%Harmonic phase0-359.99Harmonic setting accuracy(10%±0.1%)RD(2)Power Energy Measurement ErrorActive power energy0.05%RG or 0.02% RGReactive power energy0.1%RGPower Pulse OutputPower pulse typeactive pulse, reactive pulseActive power pulse output5V, 10mAPulse output frequencyMax 50kHzPower Pulse InputPulse constant set range(1--599999999)/kwhEnergy pulse typesupport active and reactive pulse, the highest frequency power pulse input is 200KHz.Meter PositionPosition3, 6, 12, 20, 24, 40, 48pcs meterStandardStandardIEC 62053-21,22, 23; IEC 60736; ANSI C12.20-2002;JJG 597-2005; JJG596-2012; JJG 1085-2013; JJF 68-2019;DL/T 826-2002; DL/T 1478-2015; DL/T 448-2016;EN 50470-1, EN 50470-2, EN-50470-3; IEC 61010;SafetyIsolation protectionIEC 61010-1:2001Measurement Category300 V CAT III, 600 V CAT IIDegree of protectionIP20Declaration of conformityCE & CNAS certifiedMechanical parametersDimensions (W×D×H) (mm)Cabinet size: 800 * 600 * 1850mm (L * W * H).Bench size: 2*2400 * 760 * 1846mm (L * W * H).Weight (kg)About 200Environmental conditionsAmbient temperature0°C to +40°CRelative humidity35%-85%(1) RG means range, the same as below;(2) RD means the setted harmonic content, harmonic can be a single output, also multiple output.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...