IPDB › China Industry › Instruments & Meters › Analysis Instrument
China, Chinese IEC60044 Current Transformer Analysis CT Meter Automatic CT PT Analyzer2 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Analysis InstrumentCT PT AnalyzerCT Analyzer
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
Preview:
Product Description IEC60044 Current Transformer Analysis CT Meter Automatic CT PT Analyzer Product Description Equipped with fully automated testing sequence function. Users only need to connect the line once, and GDVA-405 CT PT Analyzer can automatically complete all testing items except for burden testing.The GDVA-405 CT PT Analyzer is an advanced and state-of-the-art professional instrument specifically engineered to provide comprehensive testing and analysis capabilities for current transformers (CTs) and potential transformers (PTs). With its cutting-edge technology and precise measurement capabilities, this instrument plays a crucial role in the industry by facilitating accurate assessment and evaluation of transformer performance.Built with the latest advancements in testing equipment, the CT PT Analyzer offers a wide range of features and functionalities that enable thorough examination of CTs and PTs. It is designed to meet the stringent requirements of the industry, ensuring reliable and accurate results.Test ItemsTest Items by GDVA-405 CT PT Analyzer:Tests for Current TransformerTests for Potencial Transformer1) Turn ratio detection2) Ratio and angle error check3) Polarity test4) Excitation characteristic test5) Secondary winding resistance measurement and secondary burden measurement6) 5% and 10% error curve measurement7) Transient characteristics analysis8) Automatic nameplate inference9) Knee point voltage/current10) Accuracy Limit Factor (ALF)11) Instrument security factor (FS)12) Secondary time constant (Ts)13) Remanence coefficient (Kr)14) Accuracy15) Saturation and desaturation inductance16) Knee point electromotive force17) Limit electromotive force18) Area factor19) Iron core analysis and core hysteresis loop measurement1) Turn ratio measurement2) Ratio and angle error check3) Polarity test4) Excitation characteristic test5) Primary winding resistance test6) Secondary winding resistance test7) Secondary burden measurement Technical ParameterTechnical Parameter of GDVA-405 IEC60044 Transformer CVT Test Machine CT Meter Automatic CT PT Analyzer 1.Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC61869,IEC60044-5, C57.132.Power supply: AC220V±10%, 50/60Hz±10%3.Voltage output: 0.1-180V (AC)4.Current output: 0.001-5A(RMS)5.Power output: 500VA6.Maximum knee voltage measurement: 60KV7.Current measurement: Range: 0-10A (automatically change range in 0.1/0.4/2/10A) Error: <±0.1%+0.01%FS8.Voltage measurement: Range: 0-200V (automatically change range in 1V/10V/70V/200V) Error: < ±0.1%+0.01%FS9.Turns ratio measurement: Range:1-35000 1-2000 error<0.05% 2000-5000 error<0.1% 5000-35000 error<0.2%10.Phase measurement: error: ±2min; resolution: 0.01min.11.Winding resistance measurement: Range: 0-8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm) Error: < 0.2%RDG+0.02%FS Maximum resolution: 0.1mΩ12.Temperature measurement:-50~100 Celsius degree; error<3 Celsius degree.13.CT Secondary burden: Range: 0-160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm) Error: <0.2%RDG+0.02%FS Maximum resolution: 0.001ohm14.PT Secondary burden: Range: 0-80kohm (automatically change range in 800ohm/8kohm/80kohm) Error :<0.2%RDG+0.02%FS Maximum resolution: 0.1ohm15.PT ratio measurement: Range: 1-35000 1-10000 error<0.1% 10000-35000 error<0.2%16.PT ratio error measurement: Typical error <0.05%, Maximum Error<0.1%.17.PT phase angle measurement: maximum error < 3min.18.Memory capacity: >1000 groups test results.19.Working condition: temperature: -10oC~50oC; moist: ≤90% Other Functions:IEC60044 Current Transformer Testing CT Meter Automatic CT PT Analyzer 1) Make evaluation for test results according to selected standards.2) Make word report for test result.3) Make word reports one time for multi-group test records on the PC.4) Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test.5) Compare excitation curves with saved excitation curves in the same window. Testing SiteSoftware About UsContact usIf you are interested in our GDVA-405 Automatic CT PT Analyzer or have any questions, please feel free to contact us.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...