IPDB › China Industry › Instruments & Meters › Analysis Instrument
China, Chinese Biobase Lab Gas Chromatograph for Laboratory Bk-Gc78201 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Analysis InstrumentChromatography Spectroscopy InstrumentMobile Gas ChromatographGas Chromatography Spectroscopy Instrument
Biobase Biosun Co., Ltd.
Preview:
Product Description Product DescriptionBIOBASE Gas Chromatograph BK-GC7820Features:1. 5.7-inch LCD display indicates temperature,time andgas flow.2. Self-test, power protection, keyboard lock, automatic ignition andantipower mutation interference function.3. Can connect with Internet,realize data transfer and program upgrade automatically.4. Equipped with a flame ionization detector (FID), and TCD, ECD, FPD, NPD are optional. Can install3 detectors at the same time.5. Can install packed column and capillary column at the same time6. Double column compensation function,which can effectively restrain baseline drift and theinfluence of background noise.7. Large capacity oven (300*280*180mm) can hold 2 pcs 0.32mm diametercapillary column (length: 80m).8. Better thermal insulation effect: when the temp. of oven,vaporizing chamber and detector reach 300oC, the max. temp. of outer chamber is 40oC.9. With chromatography workstation software to process data. Product ParametersModelBK-GC7820OvenTemp. RangeRT~450oCTemp. Accuracy≤±0.1oCTemp. Program16-phaseMax. Temp. Heating Rate40oC/minDetectorHydrogen Flame Ionization Detector (FID)Detection limit:≤3×10^12g/s(Sample:n-hexadecane)Baseline drift:≤1x10^13A/30minLinear range:≥10^7ThermalConductivityDetector (TCD) (Optional)Sensitivity: >10000mv.ml/mg(Sample: n-hexadecane)Linear range:≥10^5Electron Capture Detector (ECD) (Optional)Detection limit:≤1×10-14g/ml(Sample:n-hexadecane δ-666)Linear range: ≥10^4Flame Photometric Detector (FPD) (Optional)Detection limit:≤2×10^11g/s(S ofthiophene)Detection limit:≤1×10^12g/s(P ofmethyl parathion)Linear range (S): ≥10^3Linear range (P): ≥10^4Nitrogen and Phosphorus Detector (NPD) (Optional)Detection limit:≤1×10^12g/s(Azobenzene)Detection limit:≤1×10^12g/s(Marla sulfur phosphorous)Linear range: ≥10^3Power SupplyAC110/220V±10%, 50/60HzStandard AccessoryFID detector, Chromatography workstation softwareOptional AccessorySample injection system, TCD, ECD, FPD and NPD detector, Chromatographic column.Package Size (W*D*H)800*570*650mmGross Weight75kgOne-stop servicePackaging & ShippingAfter Sales ServiceContact Dara for low price
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...