IPDB › China Industry › Instruments & Meters › Analysis Instrument
China, Chinese Multichannel Potentiostat Galvanostat 4-Channel Potentiostat CS310X (Opion B)1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Analysis InstrumentOther Analysis InstrumentsMultichannel PotentiostatPotentiostat
Wuhan Corrtest Instruments Corp., Ltd.
Preview:
Product Description Corrtest Multichannel potentiostat/ galvanostat/EIS is a versatile instrument offering 8 slots. Multichannel potentiostat/ galvanostat model CS310X (Option B) is the 4-channel potentiostat. 4 slots are occupied with potentiostat boards. The rest 4 slots are idle for future adding potentiostat board(s). Option B equals that you have 4 sets single-channel independent potentiostat/galvanostat in one chassis.EIS module (10μHz~1MHz) is equipped in all 4 channels. Each channel potential control range is ±10V, current control range ±1A, can meet experiment requirement for most people.Full floating module and electrical isolation design guarantee each channel is totally independent, which ensures accurate data and efficient simultaneous measurements.4- channel potentiostat/galvanostatApplication- Reaction mechanism of Electrosynthesis, electrodeposition (electroplating), anodic oxidation.- Electrochemical analysis, electro-catalysis, sensor; - New energy materials, advanced functional materials, photoelectronic materials;- Corrosion study of metals in water, concrete and soil etc;- Fast evaluation of corrosion inhibitor, water stabilizer, coating and cathodic protection efficiency.There are 4 basic options for CS310X: Option A: 4-channel with EIS on one channel Option B: 4-channel, with EIS on all four channelsOption C: 8-channel, with EIS on one channel Option D: 8-channel, with EIS on all 8 channelsThe number of channel and EIS module can be customized.More channels can be added by potentiostat boards to be installed on current deviceEIS can be upgraded online.Thanks to the expandable slot design, Customers can open the chassis and install the potentiostat board to increase the number of channels. Details as below:ModelCS310X OptionsOption AOption BOption COption DNumber of channels 4488Max. current on each channel±1A±1A±1A±1APotential range on each channel±10V±10V±10V±10VEIS (10μHz~1MHz)Included on 1 channel onlyIncluded on all 4 channelsIncluded on 1 channel onlyIncluded on all 8 channelsStandard supplyInstrument host CS310X-1 setCS studio6 software, Power cable - 1 piece, Ethernet cable - 1 pieceElectrode cable -8 pcs Dummy cell, Manual Instrument host CS310X-1 setCS studio6 software, Power cable - 1 piece, Ethernet cable - 1 pieceElectrode cable -16 pcs Dummy cell, Manual Simultaneous Measurements CS310X can run the same experiment on all channels or different experiments on each channel simultaneously. It is beneficial for batch electrochemical tests.Technical Advantages Switchable floating and earthing mode All CS potentiostats/galvanostats can switch between the floating and earthing modes, and this strategy is beneficial for studying electrochemical systems in which the working electrodes are intrinsically ground, such as autoclaves, in-site concrete structures and multi-working electrodes requiring isolation, etc.High-bandwidth EIS with the help of built-in digital FRA and arbitrary signal generator, as well as the high input impedance (1013 W), the CS potentiostat is particularly suitable for EIS measurements of high-impedance systems (such as coating, membrane, concrete, etc.) Based on the DC bias compensation technique, CS potentiostats can conduct EIS tests under different charge/discharge states of batteries, making them suitable for ultra-low resistance systems, such as power batteries, fuel cells, water-splitting equipment, etc.Multiple electrode configurationsCS potentiostats support 2-, 3-, or 4-electrode configurations and can measure the galvanic current via built-in zero resistance ammeter circuits.Independent multiple channels For CS 310X multi-channel potentiostat, each channel is completely independent. It can be used for the electrochemistry measurements of multiple cells or multiple working electrodes in a cell.User-defined sequence testCS Studio 6.0 for Windows software supports user-defined sequence tests ("combination test"), which can facilitate automatic testing according to user-defined experiment sequences. Sequence Test: corrosion tests Sequence Test: Pseudocapacitor testsPower boosterThrough CS2020B/CS2040B/CS2100B booster, the CS potentiostats can extend their output current up to ±20A/40A/100A, meeting the growing requirements in fuel cells, power batteries, electroplating etcSoftware development kit (SDK)All CS potentiostats run under the control of CS Studio 6.0 for Windows (CSS 6.0). The CSS6.0 supports third-party languages, such as LabVIEW, C, C++, C#, VC, Python and others. Some API general interfaces and development examples can be supplied with the CS potentiostats. Through the SDK, customers can implement user-defined test methods. Real-time data saving CSS 6.0 saves experimental data timely, even if the experiment is accidentally interrupted by a power failure or computer shutdown. CSS 6.0 supports several data formats compatible with Originpro and Microsoft Excel. Versatile data analysis functionsCSS 6.0 provides robust functions, including various electrochemical measurements and data analysis. It can complete Tafel plot fitting, CV derivation, integration and peak height analysis, EIS equivalent circuit fitting, etc.3, 4 parameter polarisation curve fitting. EIS fitting Electrochemical noise spectrum analysis Pseudo-capacitance calculation GCD-specific capacitance, efficiency calculation Mott-Schottky analysis CV curve analysisActivation/re-passivation curve analysis Specifications Specifications Number of channels with boards: 4Channel insulation resistance: >100MΩCommunication: EthernetLower-pass filter: covering 8-decadePotential control range: ±10VConstant current control range: ±1A on each channelPotential accuracy: 0.1%×full range±1mV Current accuracy: 0.1%×full rangePotential resolution:10μV(>100Hz), 3μV(<10Hz)Current resolution: 1pAPotential rise time: <1μs(<10mA), <10μs(<2A)Current range: 2nA ~1A, 10 rangesReference electrode input impedance: 1012Ω||20pFMaximum current output: 1ACompliance voltage: ±21VCurrent increment during scan: 1mA @1A/msCV and LSV scan rate: 0.001mV~10000V/sPotential increment during scan: 0.076mV@1V/msCA and CC pulse width: 0.0001~65000sDPV and NPV pulse width: 0.0001~1000sSWV frequency:0.001~100KHzCV minimum potential increment: 0.075mVAD data acquisition:16bit@1MHz,20bit @1kHzIMP frequency:10μHz~1MHzDA resolution:16bit, setup time:1μsCurrent and potential range: automatic Operating System requirements: Windows 10 /11Weight: 12.5 Kg Dimensions: 40*40*14cm Electrochemical Impedance Spectroscopy (EIS)Signal generatorFrequency range: 10μHz~1MHzAC signal amplitude: 1mV~2500mV Frequency accuracy: 0.005%Signal resolution: 0.1mV RMSDDS output impedance: 50ΩDC Bias: -10V~+10VWave distortion: <1%Waveform: sine wave, triangular wave, square waveScan mode: Logarithmic/linear, increase/decreaseSignal analyzerMaximum integral time:106 cycles or 105sMeasurement delay:0~105SMinimum integral time:10ms or the longest time of a cycleDC offset compensationPotential compensation range: -10V~+10VCurrent compensation range: -1A~+1ABandwidth adjustment: automatic and manual, 8-decade frequency range TechniquesStable polarizationOpen Circuit Potential (OCP)Potentiostatic (I-T curve)GalvanostaticPotentiodynamic (Tafel plot)Galvanodynamic (DGP)Transient PolarizationMulti Potential StepsMulti Current StepsPotential Stair-Step (VSTEP)Galvanic Stair-Step (ISTEP)Chrono MethodChronopotentiometry (CP)Chronoamperametry (CA)Chronocaulometry (CC)VoltammetryLinear Sweep Voltammetry (LSV)Cylic Voltammetry (CV)Staircase Voltammetry (SCV) #Square Wave Voltammetry (SWV) #Differential Pulse Voltammetry (DPV) #Normal Pulse Voltammetry (NPV)#Differential Normal Pulse Voltammetry (DNPV) #AC Voltammetry (ACV)2nd harmonic AC Voltammetry (SHACV)Fourier Transform AC Voltammetry (FTACV)# there is correspinding Stripping VoltammetryElectrochemical Impedance Spectroscopy (EIS)Potentiostatic EIS (Nyquist, Bode)Galvanostatic EISPotentiostatic EIS (Optional freq.)Galvanostatic EIS(Optional freq.)Mott-SchottkyPotentiostatic EIS vs. Time (Single freq.)Galvanostatic EIS vs. Time (Single freq.)Corrosion MeasurementsPotentiodynamic (Tafel plot)Cyclic polarization curve (CPP)Linear polarization curve (LPR)Electrochemical Potentiokinetic Reactivation (EPR)Electrochemical Noise (EN)Zero resistance Ammeter (ZRA)Battery testBattery Charge and DischargeGalvanostatic Charge and Discharge (GCD)Potentiostatic Charging and Discharging(PCD)Potentiostatic Intermittent Titration Technique(PITT)Galvanostatic Intermittent Titration Technique(GITT)
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...