IPDB › China Industry › Manufacturing & Processing Machinery
China, Chinese Lab Single Cell Flotation Machine for Mineral/Coal/Nonferrous Metals Single Groove Flotation Machine1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Mineral SeparatorFloation MachineMining Floation Machine
Jinan Chenji International Trade Co., Ltd.
Preview:
Product Description Product DescriptionPurpose and scope of application XFD-12 laboratory multi-tank flotation machine is suitable for the flotation of colored, ferrous, non-metallic and coal below -35 mesh; it can be used for flotation of 125-3000 grams of flotation samples Select test.Specification Diameter of impeller: 54mm 73mm 95mm Flotation cell volume: 500ml 750ml 1000ml 2000ml 4000ml 8000mlrecirculating drum: φ78×64mm φ60×30mm φ100×102mm φ78×42mm` φ60×16mm φ100×50mmImpeller speed : 0-2750r/minuteMotor JW6324: 250W 2800r/minuteSize: 550 ×380×830 mm Introduction to the structure of XFD-12 laboratory flotation machine : is composed of the following main components: lifting mechanism, stepless speed change mechanism, body part, stator, rotor part and control switchAll parts are connected to the column body. The main shaft rotates clockwise, the motor drives the impeller to rotate through the main shaft, and the speed of the impeller can be adjusted by rotating the gearbox handwheel. Adjust the knob of the inverter to set the impeller speed. The main body of the main shaft is lifted and lowered by the motor driving the gear through the gear box, and after driving the lift to the desired position, press the stop switch. When descending, press the descending button, and it will automatically stop when it reaches the bottom due to the travel switch. Note: When changing the lift, you must press the stop button before changing the lift. When lifting and lowering, the operator should keep away from the tank body and fix it on the square hole of the base by four cylindrical pins at the bottom of the tank. Installation, adjustment and operation method The flotation machine is installed on the workbench, and the level can be adjusted with four base screws; when the motor is connected to electricity, the rotation direction of the gas should be checked, and the main shaft impeller driven by the motor is required to rotate clockwise; The speed is regulated by the frequency converter. The speed can also be adjusted while the machine is running; the speed can be displayed on the LCD meter of the control panel. In addition, the machine is equipped with a shaking handle, which can also be adjusted to suit the needs or fine-tuning of the stirring conditions. It should be noted that before the electric lift, the handle should be pulled out, and then folded to the inside of the rocker to prevent injury to personnel during the electric lift, and personnel should not be close to the rocker during the electric lift. Impeller, stator and hollow shaft can be replaced. The impeller is connected with the right-handed screw of the main shaft, the stator is connected with the left-handed screw of the hollow sleeve, and the hollow shaft is connected with the left-handed head of the machine head. When replacing, pay attention to the direction of rotation; The circulating cylinder is evenly connected with the stator by three rubber belts; 5. Maintenance and attention Matters The valve on the hollow shaft is the main valve for cutting off and connecting the gas circuit, and the valve on the flowmeter is a fine-tuning valve. Pay attention to the opening and closing sequence to prevent the slurry from rushing into the flowmeter. When opening, it should be: start the motor - open the main valve - open the fine-tuning valve; when it is stopped, it should be: close the main valve - stop the motor. The sealing ring at the upper end of the hollow shaft should be checked regularly to prevent the slurry from leaking into the bearing due to damage. After installation and maintenance, check the air tightness in clean water at the beginning of operation, that is, close the main valve, start the main shaft, and no air bubbles will be ejected around the stator after starting. is the highest RPM without cramping air from the recirculating cylinder.Purpose and scope of applicationXFD-12 laboratory multi-tank flotation machine is suitable for the flotation of colored, black, non-metallic and coal below -35 mesh; it can be used for flotation test of 125-3000 grams of flotation samples. Technical Parameter & Specification No.NameIIIIIIUnit1Diameter of impeller φ54φ73φ95mm2flotation cellvolume 5007501000200040008000mm3`recirculating drumφ78×64φ60×30φ100×102 mm φ78×42`φ60×16 φ100×50 4Impeller speed r/m0-27505MotorJW6324250W 2800r/m6Appearance size550 ×380×830mm7Weight kgsStructure Instruction XFD-12 laboratory flotation machine consists of the following main components: lifting mechanism, continuously variable speed change mechanism, body part, stator, rotor part and control switch.All parts are connected to the column body. The main shaft rotates clockwise, the motor drives the impeller to rotate through the main shaft, and the speed of the impeller can be adjusted by rotating the gearbox handwheel. Adjust the knob of the inverter to set the impeller speed.The main body of the main shaft is lifted and lowered by the motor driving the gear through the gear box, and after driving the lift to the desired position, press the stop switch. When descending, press the descending button, and it will stop automatically when it reaches the bottom due to the travel switch.Note: When changing the lift, you must make sure to press the stop button before changing the lift. During the lifting operation, the operator should keep away from.The groove body is fixed on the square hole of the base by four cylindrical pins at the bottom of the groove.Installation, adjustment, operation methodThe flotation machine is installed on the workbench, and the level can be adjusted with four base screws;When the motor is connected to electricity, the direction of gas rotation should be checked, and the main shaft impeller driven by the motor should be required to rotate clockwise;The speed of the flotation machine is regulated by the frequency converter. The speed can also be adjusted when the machine is running; the speed can be displayed on the LCD meter of the control panel.In addition, the machine is equipped with a shaking handle, which can also be adjusted to suit the needs or fine-tuning of the stirring conditions. It should be noted that before the electric lift, the handle should be pulled out, and then folded to the inside of the rocker to prevent injury to personnel during the electric lift, and personnel should not be close to the rocker during the electric lift. Impeller, stator and hollow shaft can be replaced. The impeller is connected with the right-hand screw of the main shaft, the stator is connected with the left-hand screw of the hollow sleeve, and the hollow shaft is connected with the left-hand screw of the machine head. When replacing, pay attention to the direction of rotation;The circulating cylinder is connected to the stator equally by three rubber belts;Maintenance and precautionsThe valve on the hollow shaft is the main valve for cutting off and connecting the gas circuit, and the valve on the flowmeter is a fine-tuning valve. Pay attention to the opening and closing sequence to prevent the slurry from rushing into the flowmeter. When opening, it should be: start the motor - open the main valve - open the fine-tuning valve; when it is stopped, it should be: close the main valve - stop the motor.The sealing ring at the upper end of the hollow shaft should be checked regularly to prevent the slurry from leaking into the bearing due to its damage.After installation and maintenance, check the air tightness in the clean water at the beginning of operation, that is, close the main valve, start the main shaft, and no air bubbles will be ejected around the stator after starting. This is the highest RPM without cramping air from the recirculating cylinder.After the flowmeter is disconnected from the system, the suction volume of the machine changes greatly, so be careful when using it. Wearing parts & accessories list NO.DrawingnameSpecificationQtyNotice1 Skeleton oil seal16*30*103 2 Bearing63032 No. /NameQtyNotice1 panning dish1 2 One-way stirring impeller1 3 wrench1 4 Two-way stirring impeller1 5 scraper6 XFD-12 Packing List(Specification: 0.5, 0.75, 1.0, 2,4, 8L)No.NameUnitQtyNotice1XFD-12 multi-slot flotation machineSet1 2tankPC6Random shipments 1PC3Stator φ100PC1 4Stator φ132PC1 5Stator φ78PC1 6Impeller φ54PC1 7Impeller φ73PC1 8Impeller φ95PC1 9Circulating cylinder φ78×64, φ28×24PCEach 11 install on the main machine10Circulating cylinder φ100×102, φ100×50PCEach 1 11Circulating cylinder φ60×30, φ60×16PCEach 1 12One-way stirring bladePC1 13Two-way stirring bladePC1 14scraperPC6 15wrenchPC1 16Bearing 6303PC2 17Skeleton oil sealPC3 18A-type Allen key 3, 4PC1
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...