IPDB › China Industry › Manufacturing & Processing Machinery
China, Chinese TMAXCN Brand 3/4 Analysis Stations 4 Degas Stations Aperture and Surface Area Analyzer1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Other Mixing EquipmentSurface Area AnalyzerAperture Analyzer
Xiamen Tmax Battery Equipments Limited
Preview:
Product Description 3/4 Analysis Stations 4 Degas Stations Aperture and Surface Area Analyzer3H-2000BET-A provides standard sample reference method, single-point and multipoint BET surface area measurements with speed, accuracy, and reliability. Samples having surface areas from 0.01 m2/g to over 1,000 m2/g are easily accommodated. The 3H-2000A/BET-A -High Efficiency Surface Area Analyzer3H-2000BET-A measures surface area using the flowing gas method, which involves the continuous flow of an adsorptive and inert gas mixture over the sample at atmospheric pressure. The 3H-2000BET-A's reproducibility is better than 1.5%. The 3H-2000BET-A features a built-in Dewar elevator for completely automated analysis and rewarming fan for rapidly warming the sample tube to increase the speed of the sample analysis. Single injection calibration provides fast start-up and high sample throughput. Specially designed sample holders can be attached and removed from the instrument with one hand. These quick connect/disconnects have a built-in isolation valve to prevent sample contamination. The 3H-2000BET-A features a Dewar support latch system that provides one-handed convenience and safe-guards against LN2 spills. Simple in design, the 3H-2000BET-A requires minimal training time and leaves little chance of operator error. Automatic mode switching for adsorption and desorption is accomplished without operator attention. The low purchase price of the 3H-2000BET-A and its accessories make this instrument one of the most inexpensive ways for a laboratory to begin measuring BET surface area. Features1. Ultra-stable detector eliminates drift and need for constant readjustment.2. Cold trap conveniently Recessed at the side of the instrument. This placement reduces the chance of breakage .3. Single-injection calibration requires only one control setting. Adaptable to any non corrosive adsorbate mix.4. All controls and displays are at eye/arm level, out of spill zone.5. Built-in sample preparation.6. The 3H-2000BET-A features a built-in dewar elevator for completely automated analysis and rewarming fan for rapidly warming the sample tube to increase the speed of sample analysis7. The thermal conductivity detector eliminates temperature-induced drift resulting in highly repeatable results.8. Single-injection calibration provides fast start-up and high sample throughput.9. The 3H-2000BET-A features a dewar support latch system that provides one-hand convenience and safeguards against liquid nitrogen spills. Selection Guide 3H-2000A3H-2000BET-ADegas Stations44Degas MethodFlow GasFlow GasAnalysis Stations33/4Standard Sample Reference Method√ (3 test results in 30min)√ (3 test results in 30min)BET---√ (4 test results in 150min)GasMixed gas(20% Nitrogen,80%Helium)Two bottle of pure gas(Nitrogen and Helium)Total volume------Pore Size------Vacuum Pump------Cold Trap√√Reports
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...