IPDB › China Industry › Manufacturing & Processing Machinery
China, Chinese Highspeed Homogenizer Lab Disperser Emulsifier with Speed 8000-22000 Rpm1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
HomogenizerHomogenizersHigh Speed Homogenizer Machine
Super Accomplish Health Technical Co. Ltd
Preview:
Product Description Product DescriptionInternal Suction Structure: High speed homogenizer adopts internal suction homogenizing structure, which can carry out efficient homogenization, emulsification and extraction of trace organic compounds in water, lipid solubles and soluble organic solvents between two immiscible liquids.Application: Homogenizer can make the cell membrane rupture to the nuclear separation, and can be used at different speeds to make the DNA strand break, or make the large molecules into small molecules of material fracture.Working Mode: This high speed homogenizer can work continuously for no more than 3 minutes at a time. It is generally recommended to play for 1?2 minutes to pause for 1?2 minutes, which can be repeated several times.Button Adjustment:The working speed of the homogenizer can be adjusted by rotating the button. When used at high speed. It can make all kinds of animal and plant tissues to achieve the purpose of uniform mixing. When used at low speed, it can be used as a mixer.Homogenizing Function: The high speed homogenizer has a suction homogenizing function. It can emulsify the efficient homogenization between two immiscible liquids and emulsify the trace organic matter in water. Extraction of soluble substances and organic solvent soluble substances. Product Parameters Rated voltageAC220VRated frequency50/60HzInput power850WOutput power500WRated torque17.1N.cmWork modeS1(Continuous)Operation control modeCombined control knobRotating speed adjustment range (idle running)2000~28000rpmRotating speed control typeSteplessSpeed digital displayLEDTiming control range1~1000minDynamic speed detection functionYesSpeed memory functionYesOverload protection functionYesPeak torque of the sirring head17.0N.cmStirring head materialAISI 316Stirring head specifications12G 18G 20G 24G 30G 36GPermissible ambinet temperaturenot more than 40oCPermissible relative humiditynot more than 80%Size of the mixer (T×B×H)215×310×720mmWeight8.7kgStirring head Specifications12G18G24G30G36GMixing capacity (H2O)ml30~80050~150080~5000100~8000150~13000Max Viscosity tolerated(mPa.s)10002000500060007000Max temperature tolerated(oC)120120120120120Overall length(mm)215222225235238Stator diameter(mm)1218243036Stirring head materialSS316SS316SS316SS316SS316Bearing materialPTFEPTFEPTFEPTFEPTFEPeak linear speed of the rotor(m/s)1215182226Minimum height of the liquid immersed(mm)3545506065Maximum height of the liquid immersed(mm)150160165170175 Production workshopThe production of the Pyroceram Top Hotplate introduce1.Start by the blanking process for the metal partNormally the house of the Lab Dry Bath Incubator Heater machine medical was made by the steel or stainless steel of type as 316The part was beginning as the blanking1.Laser blanking machine capacity :8000*2000*10mm 2.We had about 15 pcs of the laser cutting machine in blanking workshop ,name from No1 to No 15,3.6S fully carry out in our workshop according to the iso13485,4.All of the raw material can be Traceability2.Bending process for Lab Dry Bath Incubator Heater by the press break bending machine The press brake machine is a powerhouse in the metal fabrication industry, providing an efficient and successful method to bend sheet metal into different formsTo form the metal part into the shape we need ,the first part was by the bending press and the bending die Stainless Steel :Provides great strength and resistance to corrosion, but its greater spring back the ability to revert to its original shape after bending means that it must be handled carefully. 3.Progressive die metal stamping workshop for Lab Dry Bath Incubator Heater part.Overhead Laboratory Homogenizers Hot Plate Max 716°F, 100-2000RPM Hot Plate with Overhead Rotor stator Homogenizers , 2000mL Rotor stator Homogenizers need the bracket for the motor and metal stamping part for the housing and electric connect part,The progressive die stamping can give out the huge volume and low cost for the LED Digital Hotplate Overhead Rotor stator Homogenizers Hot Plate with Ceramic Coated Lab Hotplate, 280oC Stir Plate, Overhead Mixer 3,000mL Stirring Capacity, 200-1500rpm, Stirring Bar Lab Equipment machine spare metal part.4.Welding workshop for the Overhead Rotor stator Homogenizers Hot Plate Mixer The Medical Sterilization machine need a lot of welding ,to imporve the capacity and welding quality we introduce the welding robot machine instead of labor human welding1.QTY of the welding robot :23pcs2.Capacity of the welding robot :500A3.Work station:2000*1500mm5.Plastic injection workshop for the Benchtop Rotor stator Homogenizers with Time Setting Speed Adjusting Rotor stator Homogenizers machinePlastic part was one part of theLaboratory Thermostatic Heater machineWe had about 10 sets of the plastic injection work for the Laboratory Thermostatic Heater machine.1.The capacity for plastic injection machine was :1000*850*750mm2.The max ton for plastic injection machine was 1000T6.The spare part Warehouse for the benchtop Stainless Steel Multifunction Steam Sterilization machineThe 6S was fully carry out in our warehouse with the ERP system 1.We need to know how many part in our warehouse2.We need to anticipate the part when to full fill in for all the benchtop Laboratory Thermostatic Heater with Drying Function Water Storage Tank 7.CNC machining for the benchtopHot Plate OverHead Rotor stator Homogenizers with Time Setting Speed Adjusting Rotor stator Homogenizers Mixer Machine Equipment.The rotor was the key part for the Hot Plate Rotor stator Homogenizers with Time Setting Speed Adjusting Rotor stator Homogenizers Mixer Equipment ,to make it perfect especial for the high speedHot Plate Rotor stator Homogenizers with Time Setting Speed Adjusting Rotor stator Homogenizers Mixer Machine Equipment ,we need to control the tolerance of the rotor very tight,that was why we introduce the Hot Plate OverHead Rotor stator Homogenizers with Time Setting Speed Adjusting Rotor stator Homogenizers Mixer Machine Equipment1.CNC QTY:15PCS2.Tolerance for CNC machine :0.01mm8.Hot Plate OverHead Rotor stator Homogenizers with Time Setting Speed Adjusting Rotor stator Homogenizers Mixer Machine stamping ,welding ,rolling Production process on site,the container of the Medical Sterilization Lab Equipment Vacuum Steam Hot Plate OverHead Rotor stator Homogenizers with Time Setting Speed Adjusting Rotor stator Homogenizers Mixer Machine Machine need the vacuum and seal can bear though high pressure 9.Electric part assemble to the Multifunction Steam Sterilization Machine workshop,the plc or the other computer control part connect to the machine before move to the next production procss.10.Test workshop for the Multifunction Steam Sterilization Machine All Multifunction Steam Sterilization Machine need to be test before transfer it to the warehouse.Customer visitCustomer review our Laboratory Rotor stator Homogenizers Machine workshop,We were welcome all of our customer to visit our company to review and test the ultrasonic homogenizer for Organisms, Medical, Chemistry,Our business vision was :long term business ,win-win for the futurePacking and loadingThe over sea customer always concern about the packing and loading for the High Shear Emulsifier Homogenizer with Time Setting High Shear Emulsifier Homogenizer Machine,we cant bear the lost for tiny mistake for the Vacuum Steam Machine machine ,one mistake will cause the machine broken or cant work .From the packing for Laboratory Medical Sterilization Machine to the container loading detail show as below Warehouse and stroage for the medical Medical Sterilization Machine,the temperature should be control within 18-25° for all equipment and test machine ,all the record can trace within 3 years. After market serviceThe maintain and repair guarantee for the Medical Sterilization Machine workshop was the key to the business ,when a customer bought a machine from us ,the guarantee was the most importance things customer concern.we sent out technical service team to oversea customer site for the maintain and repair for our customer .Our service for the lab equipment was not stop after the Vacuum Steam Machine Machine sold ,it was the start for our company and your company for win win situation .You use the Vacuum Steam Machine Machine we take care of the rest.ExhibitionWe take part into the MedtecChina Canton Fair (The China Import and Export Fair) exhibition every year ,hope one day we can meet each on the fairOur visionThe supplier and the customer was togeher for the future ,both parties should be in win-win situation ,so we were looking forwarder to hold hand by hand for bright future.he compact digital homogenizer unit includes a high-watt motor Utilized speed regulation with six different speed levels for accurate speed adjustment Designed with a digital control interface allows users to precisely set and monitor parameters Fitted with reusable sample tubes that come with specialized attachments or beads for effective homogenization Improved ABS and aluminium die-casting materials are used in the body's construction Built-in with safety features to reduce exposure to dangerous materials and prevent sample contamination Easily adjustable with simple cleaning Minimal maintenance with safety and long-term usabilityItem Type: Adjustable High Speed HomogenizerMaterial: ABSMotor Speed: 22000 rpmHomogenizing Knife 1: 8000-18000 rpmHomogenizing Knife 2: 8000-20000 rpmPower: 185WContinuous Working Time: 3 minutesHow to Use:Direct installation and use.packing list:1 x Homogenizer1 x Instruction Manual4 x Measuring Cup2 x Stand3 x Fixture4 x AccessoriesNote:1. The instrument should be placed on the horizontal worktable, the installation of the required homogenizing tool must be in place, turn on the power to try the machine first with a cup or vessel containing water, so that the pentalobe cutter head is submerged in the water, open the power switch, there is a slow to fast to adjust the speed knob, there is no clear metal friction sound (such as metal friction sound, shut off the power, loosening expenditure cutter 6M/M support tightening screw, the external fixed set of randomly steering up to the installation of in place, and then tighten) can work only after the completion of the work. If there is no metal friction sound, turn off the power, loosen the 6M/M support screw of the cutter and install the outer fixing sleeve in place randomly.2. Cut the plants or microorganisms to be experimented into small pieces or , put them in the randomly equipped glass ware, clamp them in the middle of the magnet bracket (heptagonal), loosen the 8M/M fastening screws of the fixed motor base, slowly move downward against the mouth of the vessel, make the homogenizing head 23mm from the bottom of the vessel as well, and then tighten the 8M/M screws.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...